Introducing ATM TECH NOW

The smart way to ATM. Get ATM repairs on demand, and take control of your business.

Device Image

Error Codes

 

CodeDescriptionMake
0No errorsTriton
0Normal StatusTranax
0Normal StatusHyosung
1Hyosung - Vault Door OpenTriton
2Comm ErrorTriton
3Status OKTriton
4Comm ErrorTriton
5CommsTriton
6CommsTriton
7CommsTriton
9Stream Feed Channel1Triton
10Stream Feed Channel2Triton
11Stream Feed Channel3Triton
12Stream Feed Channel4Triton
13CommsTriton
14CommsTriton
15CommsTriton
17Feed Failure Channel1Triton
18Feed Failure Channel2Triton
19Feed Failure Channel3Triton
20Feed Failure Channel4Triton
25Note Jammed Before DDM Channel1Triton
26Note Jammed Before DDM Channel2Triton
27Note Jammed Before DDM Channel3Triton
28Note Jammed Before DDM Channel4Triton
32Good operationTriton
33Note jammed between DDM and Exit sensorTriton
33Note Jammed Between DDM and Exit SensorTriton
34Mis-tracked note at feedTriton
34Note Jammed Between DDM and Reject SensorTriton
35Mis tracked note at double detect.Triton
35Denomination ErrorTriton
36Mistracked note at exit.Triton
36Unidentified Cassette CodeTriton
37Too long at exit.Triton
37Diverter 1 did not go to reject positionTriton
38Blocked exitTriton
38Diverter 2 did not go to reject positionTriton
39Too many notesTriton
41Miscount Channel 1Triton
42Transport error.Triton
42Miscount Channel 2Triton
43Miscount Channel 3Triton
44Bad Roller ProfileTriton
44Miscount Channel 4Triton
45Diverter errorTriton
46Exit quantifiedTriton
47Note missing at double detectTriton
48Reject rate exceeded.Triton
49Jam at exitTriton
49Too few notes dispensed Channel 1Triton
50Interference recoveryTriton
50Too few notes dispensed Channel 2Triton
51Accountancy errorTriton
51Too few notes dispensed Channel 3Triton
52RAM errorTriton
52Too few notes dispensed Channel 4Triton
53EPROM errorTriton
54Operation time-outTriton
55RAM corruptionTriton
56Link errorTriton
57Invalid Data CommandTriton
58Too many notes dispensedTriton
59Timing Wheel errorTriton
60Counting Sensor blockedTriton
61Loss of power during payment or purgeTriton
62Loss of power during paymentTriton
63RAM errorTriton
64Damaged USARTTriton
65Audible alarm active.Tidel
65Cassette ShuffledTriton
66Printer time-out.Tidel
66RAM access lockedTriton
67Card reader failure.Tidel
67Diverter1 not energized at start of dispenseTriton
68Dispensed item count not equal to requested item count.Tidel
68Diverter1 at wrong position at startTriton
69Diskette receipt write error.Tidel
69Diverter2 did not go to rejectpositionTriton
70Diskette initialization error.Tidel
70Diverter2 did not go to payment positionTriton
71Diskette write error.Tidel
71Diverter2 did not energizeTriton
72Diskette read error.Tidel
73No diskette in drive.Tidel
73Diverter2 in wrong position at start of dispenseTriton
74Spare.Tidel
75Diskette format error.Tidel
75Unable to reconcile previous journal entries-Aborting DownloadTriton
76Bad diskette.Tidel
76Communications error with EJTriton
77Door opened with no log-on.Tidel
78Item count equals zero.Tidel
78Reject box filledTriton
79Telephone line and/or modem problem(s).Tidel
79Reject box absentTriton
80Modem TX/RX problems.Tidel
80No cassette in feed channel for test dispenseTriton
81Reversal in process.Tidel
81DispenseTime-out(approximately2minutes)Triton
82Scheduler/Kernel error.Tidel
82Purge did not occur before first dispenseTriton
83Host response Message Type 97 - invalid Sequence Number.Tidel
83LVDT Double Detect out of toleranceTriton
84Host response Message Type 99 - invalid request Terminal ID.Tidel
84Purge error following dispenseerrorTriton
85Card removal display message down-load error.Tidel
86Printer paper low.Tidel
87No valid cash selections.Tidel
88Transaction file date error. (Cleared only on cold-start).Tidel
89Host response Message Type 96 - invalid message sequence.Tidel
90Host type-2 dispense amount error.Tidel
90Reject Box Absent or Not DetectedTriton
91Out of Service � must perform close-out.Tidel
91Dispenser Sensor failureTriton
92Flash memory write error.Tidel
92Error in last dispenseTriton
93RAM test failure.Tidel
93Error indouble detectTriton
94Application flash failure.Tidel
94Cash Dispenser purge failed uponpower-upTriton
95Spare.Tidel
95Multiple cassettes of the same type installedTriton
96SpareTidel
96Extension Cable ErrorTriton
97Cassette 1 emptyTidel
97Extension exit trailing edge timeoutTriton
98Cassette 2 emptyTidel
98Extension exit timeoutTriton
99Cassette 3 emptyTidel
99Extension Skew detectedTriton
100Cassette 4 emptyTidel
100Trailing edge time-out at extension entranceTriton
1012-second timeout waiting for pick. (Feed failure).Triton
101Cassette 5 emptyTidel
102Timeout at Exit SensorTriton
102Cassette 6 emptyTidel
103Thickness sensor unstableTriton
103Cassette 7 emptyTidel
104Unable to clear width sensor.Triton
104Cassette 8 emptyTidel
105Insufficient notes to learn fromTriton
105Cassette-1 low.Tidel
106FIFO errorTriton
106Cassette 2 lowTidel
107Time out waiting for FIFOTriton
107Cassette 3 lowTidel
108Cassette 4 lowTidel
108Unexpected note at double detect- width sensor did not detect noteTriton
109Time-out at Exit sensorTriton
109Cassette 5 lowTidel
110Trailing edge time-out at exit.Triton
110Cassette 6 lowTidel
111Diverter timeoutTriton
111Cassette 7 lowTidel
112Timeout waiting for leading edge at rejectTriton
112Cassette 8 lowTidel
113Timeout waiting for trailing edge at rejectTriton
113Cassette 1 zero document countTidel
114Exit blocked during purgeTriton
114Cassette 2 zero document countTidel
115Diverter timeout on purgeTriton
115Cassette 3 zero document countTidel
116Cassette 4 zero document countTidel
116Motor FaultTriton
117Cassette 5 zero document countTidel
117Timeout waiting for note to divertTriton
118Exit sensor blocked on start of dispense or learnTriton
118Cassette 6 zero document countTidel
119Diverter in dispense position on start of dispense or learnTriton
119Cassette 7 zero document countTidel
120Reject Cassette not presentTriton
120Cassette 8 zero document countTidel
121Note cassette not presentTriton
121Cassette 1 needs calibrationTidel
122Unexpected note at exitTriton
122Cassette 2 needs calibrationTidel
123Cassette 3 needs calibrationTidel
123Hardware ErrorTriton
124Diverter moved to exit position during reject purgeTriton
124Cassette 4 needs calibrationTidel
125Initial status check failedTriton
125Cassette 5 needs calibrationTidel
126Diverter moved to reject position during dispenseTriton
126Cassette 6 needs calibrationTidel
127Cassette 7 needs calibrationTidel
127Jam in TDM extensionTriton
128Error in reply from the dispenser mechanismTriton
128Cassette 8 needs calibrationTidel
129No response from the dispenser mechanismTriton
130Command not acknowledged by the dispenser mechanismTriton
131CTS (Clear To Send) line from the dispenser is not active.Triton
132Status reports bad double detect in last dispenseTriton
133+5 VDC not present on carrier detectTriton
134Exit blocked as reported by status checkTriton
135Feed sensor blocked as reported by status checkTriton
136Modem initialization failedTriton
137Print failure to journalTriton
138Printer failed while printing to the receipt printerTriton
139Printer controller not responding to commandsTriton
140Time-out waiting for printer to be readyTriton
141Paper jam reported by the controller during status check.Triton
142Dispenser returns bad command error.Triton
143PTDF ErrorTriton
144No reply from the electronic journal.Triton
145Error in reply from the electronic journalTriton
146No reply from command to electronic journalTriton
147Error in reply from electronic journal.Triton
148Write to electronic journal failedTriton
149Read from electronic journal failedTriton
150Status command to journal failedTriton
151Electronic journal fullTriton
152Electronic journal corruptTriton
153Electronic journal modeTriton
154Unknown electronic journal statusTriton
155Electronic journal modify record failureTriton
156Cassette out of service.Triton
157Erase command to electronic journal failedTriton
158Format command to electronic journal failedTriton
159Electronic journal test feature failedTriton
160Electronic journal set featured failedTriton
161Electronic journal clear feature failedTriton
162Electronic Journal get serial number failedTriton
163Terminal did not answer. This is a Triton Connect error.Triton
164Terminal did not return call. Triton Connect error.Triton
165Electronic journal not presentTriton
166Bad dispenseTriton
167Reported low cash to Triton ConnectTriton
168Software download to terminal failed.Triton
182Currency cassette low. Valid for SDD and GND mechanisms only.Triton
183Receipt printer paper is lowTriton
184Journal printer paper lowTriton
185Telephone number not configuredTriton
186Bill Size not configuredTriton
187Maximum withdrawal not configuredTriton
188PIN working key not configuredTriton
189Terminal ID not configuredTriton
190PIN Master key not configuredTriton
191Feed FailureTriton
192Communication errorTriton
193TheBaudratesettingfortheEJfailedTriton
194An Attempt to Dispense is made the Cassettes are not LockedTriton
195Receipt printer out of paperTriton
196Card reader errorTriton
197Dispenser has detected a blocked stacker during a dispense.Triton
198Dispenser did not detect note going instacker.Triton
199Cash Dispenser width errors.Triton
200Dispenser fed extra note into its stackerTriton
201Dispenser detected more than 6 errors in dispense.Triton
202Dispenser is busy.Triton
203SPED keypad is not replying to main boardTriton
204Number of bills dispensed not equal to bills requested.Triton
205SPED keypad reported tamper conditionTriton
206SPED keypad could not perform a successful command within SPED_MAX_ATTEMPTS triesTriton
207SPED not detectedTriton
208Dispenser did not reply after a dispense command.Triton
209Check Number of Notes Delivered commandfailed.Triton
210Dispenser type unknownTriton
211The reply from the Dispenser was invalid.Triton
212Wrong SPED for SuperScrip.Triton
231Card Reader Error (Smart Card)Triton
233Smart Card Reader not installedTriton
234SPED Version number is not 3DES compatibleTriton
235MAP Stack overflowTriton
236Failed to make connection to TCP/IP hostTriton
237TCP/IP device failedTriton
238Power failure during dispenseTriton
239SPED serial number changeTriton
240SPED Self Test ErrorTriton
241SPED Warning: Self Test error- low batteryTriton
242Stuck keyTriton
243Unable to display user defined surcharge screenTriton
244Min. partial dispense enabled with no doc countTriton
245Min. partial dispense enabled with no usable billsTriton
246Master password must be changed from defaultTriton
300Successful CommandTriton
301Low level in cassetteTriton
302Empty cassetteTriton
303Lifts are downTriton
304Rejected notesTriton
305Diverter failureTriton
306Failure to feed.Triton
307Transmission ErrorTriton
308Illegal command or command sequenceTriton
309Jam in Note QualifierTriton
310Cassette not properly installed.Triton
311Config record size invalidTriton
312No notes retractedTriton
313Cassette hopper map invalidTriton
314Dispenser offline - cannot resolve dispense countTriton
315Reject vault not properly installedTriton
316Delivery failure.Triton
317Reject failureTriton
318Too many notes requestedTriton
319Jam in note transportTriton
320Reject cassette almost fullTriton
321Cassette data corruptedTriton
322Main motor failureTriton
323Dispenser offline - Dispense count check errorTriton
324Reserved for warning statusTriton
325Note qualifier faultyTriton
326Note feed sensor failureTriton
327Shutter failureTriton
329Notes in delivery throatTriton
330Communication timeoutTriton
332Cassettes may have been changedTriton
333Reject vault fullTriton
339Error in throatTriton
343Sensor error or sensor coveredTriton
348Dispenser internal error.Triton
349Cassette lock faultyTriton
350Jam in note stackerTriton
351Module needs serviceTriton
353No message to resendTriton
356Error in note transportTriton
357Dispenser data size errorTriton
358Dispenser device read errorTriton
359Dispenser device record errorTriton
360Dispenser invalid return IDTriton
361Dispenser sequence errorTriton
362Dispenser device write errorTriton
363Dispenser device not foundTriton
364Dispenser device offlineTriton
365Dispenser BCC errorTriton
366Dispenser cassettes disabledTriton
367Dispenser communication error.Triton
368Dispenser cannot dispense the requestTriton
369Dispenser device resetTriton
370Dispenser - EOT errorTriton
371Dispenser com error header-trailerTriton
372Dispenser item value errorTriton
373Dispenser machine not openedTriton
374Dispenser rejected checkTriton
375Dispenser invalid requestTriton
376Dispenser multiple device errorTriton
377Dispenser device errorTriton
378Dispenser cassette lowTriton
379Dispenser unknown error codeTriton
380Dispenser setup incompleteTriton
381Dispenser cassette invalidTriton
382Dispenser cassettes disabled (ALL)Triton
383Dispense cassettes low (ALL)Triton
384Dispenser cassettes empty (ALL)Triton
385Dispenser offline- no reject vault and no hoppersTriton
386Dispenser offline - no hoppersTriton
387Dispenser offline - error-validating configurationTriton
388Dispenser offline - NMD require Reject Vault and at least one cassetteTriton
389Dispenser offline. Detected offline error check op stateTriton
390Dispenser offline - storing configurationTriton
391Dispenser sensor failure 2Triton
392Error in last dispenseTriton
393Error in double detect 2Triton
394Purge failed upon power-upTriton
395Multiple cassette of the same typeTriton
396Dispenser offline - found no reject binTriton
500SPED Read ErrorTriton
501SPED invalid return recordTriton
502SPED read type errorTriton
503SPED invalid commandTriton
504SPED invalid return IDTriton
505SPED device busyTriton
506SPED invalid requestTriton
507SPED sequence errorTriton
508SPED LRC errorTriton
509SPED no dataTriton
510SPED invalid message IDTriton
511SPED Data overflowTriton
512SPED device idleTriton
513SPED device offlineTriton
514SPED device bit stuckTriton
515SPED device attention stuckTriton
516SPED device no attentionTriton
517SPED device timeoutTriton
518SPED command sequence errorTriton
519SPED invalid command dataTriton
520SPED device resetTriton
521SPED clear keyTriton
522EJ errorTriton
523EJ data size errorTriton
524EJ bad commandTriton
525EJ invalid IDTriton
526EJ device busyTriton
527EJ invalid requestTriton
528EJ sequence errorTriton
529EJ device offlineTriton
530EJ EXT errorTriton
531EJ SOH errorTriton
532EJ STX errorTriton
533EJ BCC errorTriton
534EJ device resetTriton
535Card Reader - Data size errorTriton
536Card Reader - Device read errorTriton
537Card Reader - Invalid RecordTriton
538Card Reader - Reader type errorTriton
539Card Reader - Invalid trackTriton
540Card Reader - Invalid messageTriton
541Card Reader - Com errorTriton
542Card Reader - Device busyTriton
543Card Reader - Sequence errorTriton
544Card Reader - Invalid requestTriton
545Card Reader - LRC errorTriton
546Card Reader - No dataTriton
547Card Reader - Start sentinel not foundTriton
548Card Reader - End sentinel not foundTriton
549Card Reader - Parity errorTriton
550Card Reader - Card not removedTriton
551Card Reader - Card removed to slowTriton
552Card Reader - Device received invalid requestTriton
553Card Reader - device offlineTriton
554Card Reader - device resetTriton
555Card Reader - System timeoutTriton
556System timeoutTriton
557System device resetTriton
558System sync errorTriton
559System errorTriton
560Unknown device errorTriton
561Software errorTriton
562SPED errorTriton
563Low MemoryTriton
564Unable to access external memory deviceTriton
565Cabinet door openTriton
566Vault door openTriton
567Security module not foundTriton
568Security module com failedTriton
569Security module attached dev com failedTriton
570Security module dev port setupTriton
571Invalid default transactionTriton
572SPED key from pad cmd aborted by userTriton
573SPED keys from pad cmd verify failedTriton
574SNA comms errorTriton
575Timeout waiting to send command to dispenserTriton
576Timeout waiting to receive response from dispenserTriton
577Card reader disabledTriton
578Card reader present timeoutTriton
579SPED - Enable keypad command failedTriton
580SPED - Disable keypad command failedTriton
581SPED - Enable key from pad module failedTriton
582SPED - Disable key from pad moduleTriton
583SPED - Enable PIN entry mode failedTriton
584SPED - Disable PIN entry mode failedTriton
585SPED - Enable JETCO PIN entry mode failedTriton
586SPED - Enable JETCO PIN entry mode failedTriton
587NMD 50 required Cassette in TOP hopperTriton
588ERR PRESENTER OFFLINETriton
589ERR PRESENTER MOTOR STALLEDTriton
590ERR PRESENTER EXIT JAMTriton
591ERR PRESENTER PAPER NOT DETECTEDTriton
592ERR SPED DEVICE REPORTED FAILEDTriton
593ERR SPED IN USETriton
594ERR SPED DEVICE REPORTED COMM ERRORTriton
595ERR SPED RETURNE INVALID AMOUNT OF DATATriton
596ERR SPED INVALID SPED TYPETriton
597ERR SPED INVALID SPED COMMS PROTOCOLTriton
598ERR_SPED_INVALID_DEVICE_CLASSTriton
599ERR SPED REPORTED UNRECOGNIZED COMMANDTriton
600ERR SPED REPORTED BLOCK DOES NOT EXISTTriton
601ERR SPED REPORTED INVALID ENCRYPT MODETriton
602ERR SPED REPORTED UNSUPPORTED CLEAR OPTIONTriton
603ERR SPED REPORTED TAMPER PRESENTTriton
604ERR SPED REPORTED INVALID KEY INDEXTriton
605ERR SPED REPORTED PARENT KEY NOT LOADEDTriton
606ERR SPED REPORTED WRONG DATA LENGTHTriton
607ERR SPED REPORTED PIN RETRY TOO SOONTriton
608ERR SPED SELFTEST CRC FAILEDTriton
609ERR SPED SELFTEST CRYPTOGRAPHIC ERRORTriton
610ERR SPED SELFTEST BATTERY LOW STATUSTriton
611ERR SPED SELFTEST SERIAL NUMBER ERRORTriton
612ERR SPED TAMPER STATUS COLDTriton
613ERR SPED TAMPER STATUS FRONTTriton
614ERR_SPED_TAMPER_STATUS_BACKTriton
615ERR SPED TAMPER STATUS GRIDTriton
616ERR SPED TAMPER STATUS VOLTAGETriton
617ERR SPED SERIAL NUMBER CHANGETriton
618SPED serial number changeTriton
619NMD 100 shutter failed after resetTriton
620NMD 100 shutter OK after resetTriton
902Cassette pickup errorTriton
903All cassettes missingTriton
904CST #3 not in positionTriton
910Device Not ConnectedTriton
912Unknown DispenseTriton
915CST #3 jamTriton
916Reject Gate right sensor blockedTriton
917Note not arriving at eject sensor from reject gate timing sensorTriton
918Encryption ErrorTriton
919Consecutive reject of 5 notesTriton
920"""Dispensing cut-off note"Triton
921The requested notes are more than 150Triton
922The number of notes passed the exit is not equal to the requested numberTriton
1001No acknowledgment received.Tidel
1002Command transmit time-out.Tidel
1003Command response receive time-out.Tidel
1004Communication write failed.Tidel
1005Block check character error.Tidel
1006End of transmission character not received.Tidel
1007Special option flag set in error.Tidel
1008Invalid protocol selection.Tidel
1009FIB (Feeder/dispenser Interface Board) jumper setting error.Tidel
1010FIB not responding.Tidel
1011FIB error recovery failure.Tidel
1012Internal AnyCard logic error.Tidel
1013Spare.Tidel
1014Spare.Tidel
1015Spare.Tidel
1016Spare.Tidel
1017Spare.Tidel
1018Spare.Tidel
1019Spare.Tidel
1020Spare.Tidel
1021Spare.Tidel
1022Spare.Tidel
1023Spare.Tidel
1024Spare.Tidel
1025Spare.Tidel
1026Spare.Tidel
1027Spare.Tidel
1028Spare.Tidel
1029Spare.Tidel
1030Spare.Tidel
1031Spare.Tidel
1032Spare.Tidel
1033Feed failure.Tidel
1034Item mis-track at feed.Tidel
1035Item mis-track at doubles detector.Tidel
1036Item mis-track at exit.Tidel
1037Item too long at exit.Tidel
1038Blocked exit.Tidel
1039Too many items.Tidel
1040Timing wheel error.Tidel
1041Band roller profile error.Tidel
1042Diverter error.Tidel
1043Exit quantified error.Tidel
1044Item missing at doubles detector.Tidel
1045Reject rate exceeded.Tidel
1046Jam at exit.Tidel
1047Interference recovery.Tidel
1048Suspect exit accountancy.Tidel
1049Read-write memory error.Tidel
1050Read-only memory error.Tidel
1051Operation time-out.Tidel
1052Read-write memory corruption.Tidel
1053Link error.Tidel
1054Feed sensor blocked.Tidel
1055Exit sensor blocked.Tidel
1056Cassette low indicator.Tidel
1057Exit sensor dirty.Tidel
1058Average item thickness range error.Tidel
1059Average item length range error.Tidel
1060Soft reset failure.Tidel
1061Firmware version invalid.Tidel
1062Firmware issue number invalid.Tidel
1063Transport type invalid.Tidel
1064Currency type error.Tidel
2001Delivery failure.Tidel
2002NMD data corrupt.Tidel
2003Cassette lock faulty.Tidel
2004Spare.Tidel
2005Jam in note stacker.Tidel
2006Wrong count.Tidel
2007Reject failure.Tidel
2008Jam in note transport.Tidel
2009Main motor failure.Tidel
2010Note qualifier faulty.Tidel
2011Shutter failure.Tidel
2012Throat error.Tidel
2013Feed failure.Tidel
2014Jam in note qualifier.Tidel
2015Cassette data corrupted.Tidel
2016Cassette exit sensor failure.Tidel
2017Sensor error.Tidel
2018Spare.Tidel
2019No message to resend.Tidel
2020Power or cable(s) error.Tidel
2021Spare.Tidel
2022Spare.Tidel
2023Spare.Tidel
2024Spare.Tidel
2025Spare.Tidel
2026Spare.Tidel
2027Spare.Tidel
2028Spare.Tidel
2029Spare.Tidel
2030Spare.Tidel
2031Modem setup required - external modemTidel
2032Security module tamperedTidel
2033Spare.Tidel
2034Notes rejected.Tidel
2035No notes retracted.Tidel
2036Reject cassette full.Tidel
2037Spare.Tidel
2038Spare.Tidel
2039Module needs service.Tidel
2040No data available.Tidel
2041Command transmission error.Tidel
2042Illegal command.Tidel
2043Communications time-out.Tidel
2044Bin change - must read IDs.Tidel
2045Spare.Tidel
2046Cassette empty.Tidel
2047Lifts are down.Tidel
2048Cassette not installed.Tidel
2049Reject bin not installed.Tidel
2050Too many notes requested.Tidel
2051Notes in delivery throat.Tidel
2052Reject cassette full.Tidel
2053Spare.Tidel
2054Spare.Tidel
2055Spare.Tidel
2056Spare.Tidel
2057Spare.Tidel
2058Spare.Tidel
2059Spare.Tidel
2060Spare.Tidel
2061Spare.Tidel
2062Spare.Tidel
2063Spare.Tidel
2064Spare.Tidel
2097Cassette-1 empty.Tidel
2098Cassette-2 empty.Tidel
2099Cassette-3 empty.Tidel
2100Cassette-4 empty.Tidel
2101Cassette-5 empty.Tidel
2102Cassette-6 empty.Tidel
2103Cassette-7 empty.Tidel
2104Cassette-8 empty.Tidel
2105Cassette-1 low.Tidel
2106Cassette-2 low.Tidel
2107Cassette-3 low.Tidel
2108Cassette-4 low.Tidel
2109Cassette-5 low.Tidel
2110Cassette-6 lowTidel
2111Cassette-7 low.Tidel
2112Cassette-8 lowTidel
2113Cassette-1 zero document count.Tidel
2114Cassette-2 zero document count.Tidel
2115Cassette-3 zero document count.Tidel
2116Cassette-4 zero document count.Tidel
2117Cassette-5 zero document count.Tidel
2118Cassette-6 zero document count.Tidel
2119Cassette-7 zero document count.Tidel
2120Cassette-8 zero document count.Tidel
2121Cassette-1 needs calibration.Tidel
2122Cassette-2 needs calibration.Tidel
2123Cassette-3 needs calibration.Tidel
2124Cassette-4 needs calibration.Tidel
2125Cassette-5 needs calibration.Tidel
2126Cassette-6 needs calibration.Tidel
2127Cassette-7 needs calibration.Tidel
2128Cassette-8 needs calibration.Tidel
5001Internal AnyCard logic error.Tidel
5002ENQ transmit timeout.Tidel
5003Communications write error.Tidel
5004No ACK received.Tidel
5005Unknown command.Tidel
5006Response timeout.Tidel
5007Parameter not registered.Tidel
5008Count instruction without setup.Tidel
5009Too many items requested.Tidel
5010Invalid ISO code for parameter.Tidel
5011Invalid item length or thickness.Tidel
5012Invalid parameter.Tidel
5013Command format error.Tidel
5014Pulse motor over current detected.Tidel
5015Main motor over current detected.Tidel
5016Checksum error of log data.Tidel
5017Sensor abnormal.Tidel
5018Item at exit sensor after mechanical reset.Tidel
5019Unknown error code.Tidel
5020Invalid ISO parity.Tidel
5021Power fail during dispense.Tidel
5022FIB not responding.Tidel
5023FIB error recovery failure.Tidel
5024Dispenser download error.Tidel
5025Undefined RAS command.Tidel
5026Dispenser 24 volt power loss.Tidel
5027FIB (Feeder/dispenser Interface Board) jumper setting error.Tidel
5028Spare.Tidel
5029Spare.Tidel
5030Spare.Tidel
5031Spare.Tidel
5032Spare.Tidel
5033Cassette 1 not installed.Tidel
5034Cassette 1 pick failure.Tidel
5035Cassette 2 not installed.Tidel
5036Spare.Tidel
5037Cassette 3 not installed.Tidel
5038Spare.Tidel
5039Cassette 4 not installed.Tidel
5040Spare.Tidel
5041Reject box overflow.Tidel
5042Suspected item on transport belts.Tidel
5043Motor turning without permission.Tidel
5044Motor failure.Tidel
5045Jam between pick and potentiometer sensors.Tidel
5046Jam at potentiometer sensor.Tidel
5047Jam between potentiometer and exit sensors.Tidel
5048Check diverter gate.Tidel
5049Item too long.Tidel
5050Item too short.Tidel
5051Item thickness abnormal.Tidel
5052Spurious item detected at cassette sensor.Tidel
5053Item spacing too close.Tidel
5054Check diverter gate.Tidel
5055Potentiometer failure.Tidel
5056Empty cassette/s.Tidel
5057All cassettes need calibration.Tidel
5058Clear dispenser transport required.Tidel
5059Spare.Tidel
5060Spare.Tidel
5061Spare.Tidel
5062Spare.Tidel
5063Spare.Tidel
5064Spare.Tidel
5097Cassette-1 empty.Tidel
5098Cassette-2 empty.Tidel
5099Cassette-3 empty.Tidel
5100Cassette-4 empty.Tidel
5101Spare.Tidel
5102Spare.Tidel
5103Spare.Tidel
5104Spare.Tidel
5105Cassette-1 low.Tidel
5106Cassette-2 low.Tidel
5107Cassette-3 low.Tidel
5108Cassette-4 low.Tidel
5109Spare.Tidel
5110Spare.Tidel
5111Spare.Tidel
5112Spare.Tidel
5113Cassette-1 zero document count.Tidel
5114Cassette-2 zero document count.Tidel
5115Cassette-3 zero document count.Tidel
5116Cassette-4 zero document count.Tidel
5117Spare.Tidel
5118Spare.Tidel
5119Spare.Tidel
5120Spare.Tidel
5121Cassette-1 needs calibration.Tidel
5122Cassette-2 needs calibration.Tidel
5123Cassette-3 needs calibration.Tidel
5124Cassette-4 needs calibration.Tidel
5125Spare.Tidel
5126Spare.Tidel
5127Spare.Tidel
5128Spare.Tidel
587NMD 50 required Cassette in TOP hopperTriton
588Printer presenter offlineTriton
589Printer presenter motor stalledTriton
590Printer presenter exit jam.Triton
591Printer presenter paper not detectedTriton
592SPED reported Command failedTriton
593SPED in useTriton
594SPED reported COMM errorTriton
595SPED returned invalid amount of dataTriton
596Invalid SPED typeTriton
597Invalid SPED COMMS protocolTriton
598Invalid SPED classTriton
599SPED reported unrecognized commandTriton
600SPED reported Block does not existTriton
6001No acknowledgement receivedTidel
6002Dispenser not respondingTidel
6003Communication Line errorTidel
6004Transmit timeout errorTidel
6005Response content errorTidel
6006Message check character errorTidel
6007Receive timeout errorTidel
6008Post processing errorTidel
6009FIB error recovery failureTidel
601SPED reported invalid encryptTriton
6010FIB not respondingTidel
6011Dispenser jumper setting errorTidel
6012Power failure during dispenseTidel
6013No acknowledgement receivedTidel
6014Dispenser not respondingTidel
6015No acknowledgement receivedTidel
6016Dispenser not responsdingTidel
6017SpareTidel
6018SpareTidel
6019SpareTidel
602SPED reported unsupported clear optionTriton
6020SpareTidel
6021SpareTidel
6022SpareTidel
6023SpareTidel
6024SpareTidel
6025SpareTidel
6026SpareTidel
6027SpareTidel
6028SpareTidel
6029SpareTidel
603SPED reported tamper present.Triton
6030SpareTidel
6031SpareTidel
6032SpareTidel
6033Feed failureTidel
6034Note separation errorTidel
6035Sensed double detect before pickTidel
6036Pick sensor blockedTidel
6037Delay at exit sensorTidel
6038Exit sensor blockedTidel
6039Timing wheel errorTidel
604SPED reported invalid key index.Triton
6040Double detected before pickingTidel
6041Diverter errorTidel
6042Exit counter errorTidel
6043No note at double detectTidel
6044Reject rate exceededTidel
6045Reject sensor errorTidel
6046Exit sensor initialization errorTidel
6047Empty cassette(s)Tidel
6048Double detect sensor abnormalTidel
6049Dispenser eror code unknownTidel
605SPED reported parent key not loaded.Triton
6050Dispense timeoutTidel
6051Purge did not operateTidel
6052Purge timeoutTidel
6053Bad command to sensorTidel
6054Cassette 1 pick sensor blockedTidel
6055Cassette 2 pick sensor blockedTidel
6056Cassette 3 pick sensor blockedTidel
6057Cassette 4 pick sensor blockedTidel
606SPED reported wrong data lengthTriton
607SPED reported PIN retry too soonTriton
608SPED self test CRC failedTriton
609SPED self test Cryptographic error.Triton
610SPED self test Battery low statusTriton
611SPED self test serial number errorTriton
612SPED tamper status cold.Triton
613SPED tamper status frontTriton
614SPED tamper status backTriton
615SPED tamper status grid.Triton
616SPED tamper status voltageTriton
617SPED serial number changedTriton
618SPED tamper status CRCTriton
619NMD 100 Shutter FAILED after resetTriton
620NMD100 Shutter OK after resetTriton
621SPED unrecoverable device tamperTriton
7001Dispenser will not acknowledgeTidel
7002Dispenser not respondingTidel
7003Dispenser line errorTidel
7004Dispenser transmit timeoutTidel
7005Dispenser response format errorTidel
7006Dispeser block check char errorTidel
7007Dispenser response timeoutTidel
7008Dispenser Post EventTidel
7009FIB error recovery failureTidel
7010FIB not respondingTidel
7011Dispenser jumper setting errorTidel
7012Power failure during dispenseTidel
7013Empty cassettes(s)Tidel
7014All cassettes out of serviceTidel
7015Left cassette 4 sensor blockedTidel
7016Right cassette 4 sensor blockedTidel
7017Left cassette 3 sensor blockedTidel
7018Right cassette 3 sensor blockedTidel
7019Left cassette 2 sensor blockedTidel
7020Right cassette 2 sensor blockedTidel
7021Left cassette 1 sensor blockedTidel
7022Right cassette 1 sensor blockedTidel
7023Left sensor before RVDT blockedTidel
7024Right sensor before RVDT blockedTidel
7025Left sensor before diverter blockedTidel
7026Right sensor before diverter blockedTidel
7027Left reject sensor blockedTidel
7028Right reject sensor blockedTidel
7029Left sensor after diverter blockedTidel
7030Right sensor after diverter blockedTidel
7031Left eject sensor blockedTidel
7032Right eject sensor blockedTidel
7033Pick FailureTidel
7034Jam between cassette 1 and RVDTTidel
7035Jam between cassette 2 and RVDTTidel
7036Jam between cassette 3 and RVDTTidel
7037Jam between cassette 4 and RVDTTidel
7038Jam between RVDT and diverterTidel
7039Jam between Diverter and exitTidel
7040Jam between Diverter and rejectTidel
7041Note at exit too longTidel
7042Note at exit too shortTidel
7043BLDC motor failueTidel
7044Sensor errorTidel
7045Motor failure check 24V powerTidel
7046Abnormal feed speedTidel
7047Diverter failed Note(s) rejectedTidel
7048Diverter failed Note(s) ejectedTidel
7049Diverter failed during initializationTidel
7050Sensor error notes mistrackedTidel
7051Notes skew. Check condition of notesTidel
7052Too many notes requestedTidel
7053Too many notes rejectedTidel
7054TCDM unknown commandTidel
7055Potentiometer errorTidel
7056Reject cassette missingTidel
7057TCDM Dip switch 3 not setTidel
7058Warning cassette missingTidel
7059Warning reject cassette almost fullTidel
7060Dispensing from wrong cassetteTidel
7061Clear dispenser errors ejected notesTidel
7062All cassettes need calibrationTidel
7063SpareTidel
7064SpareTidel
1Time-outTriton
11019100"LOST CARD DEV_MCU"Hyosung
11039100"LOST CARD & SLIP DEV_MCU | DEV_SPR"Hyosung
11059100"LOST PB DEV_PBM"Hyosung
11069100"LOST SLIP DEV_SPR"Hyosung
100Good operationTriton
1001ADMIN LOG ONVerifone
1001ADMIN LOG ONTranax
1001Administrator entered the programWRG
1002ADMIN BALANCEVerifone
1002ADMIN BALANCETranax
1002Administrator got the balanceWRG
1003ADMIN SETVerifone
1003ADMIN SETTranax
1003Administrator set the balanceWRG
1004ADMIN ADDVerifone
1004ADMIN ADDTranax
1004Administrator added to the balanceWRG
1005ADMIN ASUBVerifone
1005ADMIN ASUBTranax
1005Administrator subtracted from the balanceWRG
1006ADMIN LTXVerifone
1006ADMIN LTXTranax
1006Administrator printed a copy of the receipt for the last customer transactionWRG
1007ADMIN SUMVerifone
1007ADMIN SUMTranax
1007Administrator printed the summary reportWRG
1008ADMIN EVENT LOG PRINTVerifone
1008ADMIN EVENT LOG PRINTTranax
1008Administrator printed the event logWRG
1009ADMIN JOURNAL PRINTVerifone
1009ADMIN JOURNAL PRINTTranax
1009Administrator printed the electronic journalWRG
1012-second timeout waiting for pick. (Feed failure). Triton
1010ADMIN DIAGVerifone
1010ADMIN DIAGTranax
1010Administrator ran diagnosticsWRG
1011ADMIN CNFG DATEVerifone
1011ADMIN CNFG DATETranax
1011Administrator set the dateWRG
1012ADMIN CNFG TIMEVerifone
1012ADMIN CNFG TIMETranax
1012Administrator set the timeWRG
1013ADMIN CNFG EDITVerifone
1013ADMIN CNFG EDITTranax
1013Administrator edited the Terminal ConfigurationWRG
1014ADMIN CNFG PRINTVerifone
1014ADMIN CNFG PRINTTranax
1014Administrator printed the configurationWRG
1015WORKING KEY DL NEEDEDVerifone
1015WORKING KEY DL NEEDEDTranax
1015"Working Key needed- Enter the Admin menu select DIAG Select WKEY Screen should show Dialing--Connected--New working key updated The display will go back to the DIAGNOSTICS screen"WRG
1016Administrator printed the cash logWRG
1017Administrator entered the Host menuWRG
1018Administrator edited the Host configurationWRG
1019Master Key 1L enteredWRG
102Timeout at Exit Sensor Triton
1020Master Key 1R enteredWRG
1021master Key 2L enteredWRG
1022Master Key 2R enteredWRG
1023Administrator changed the download terminal identifierWRG
1024Administrator changed the download applicationWRG
1025MAC Key 1L enteredWRG
1026MAC Key 1R enteredWRG
1027MAC Key 2L enteredWRG
1028MAC key 2R EnteredWRG
103Thickness sensor unstableTriton
10301DEV_PINTranax
1030100DEV_PIN (Key data error from host)Tranax
1030100DEV_PIN (Key data error from host)Hyosung
104Unable to clear width sensor. Triton
105Insufficient notes to learn from Triton
106FIFO error Triton
107Time out waiting for FIFO Triton
108"Unexpected note at double detect
width sensor did not detect note "Triton
109Time-out at Exit sensor Triton
11No connectTriton
110Trailing edge time-out at exit. Triton
1101CASH LOADER LOG ONVerifone
1101CASH LOADER LOG ONTranax
1101Cash Loader got the balanceWRG
1101910LOST CARD DEV_MCUTranax
1101910"LOST CARD & SLIP"" DEV_MCU | DEV_SPR"Hyosung
1102CASH LOADER BALANCEVerifone
1102CASH LOADER BALANCETranax
1102Cash loader got the balanceWRG
1102910LOST WITHDRAW CASH DEV_CSHTranax
1102910"LOST WITHDRAW CASH"" DEV_CSH"Hyosung
1102920LOST DEPOSIT CASH DEV_CSHTranax
1102920"LOST DEPOSIT CASH"" DEV_CSH"Hyosung
1103CASH LOADER SETVerifone
1103CASH LOADER SETTranax
1103Cash loader set the balanceWRG
1103910LOST CARD & SLIP DEV_MCU I DEV_SPRTranax
1103910"LOST CARD & SLIP"" DEV_MCU | DEV_SPR"Hyosung
1104CASH LOADER ADDVerifone
1104CASH LOADER ADDTranax
1104Cash loader added to the balanceWRG
1105CASH LOADER SUBVerifone
1105CASH LOADER SUBTranax
1105Cash loader subtracted from the balanceWRG
1106910LOST SLIP DEV_SPRTranax
1106910"LOST SLIP"" DEV_SPR"Hyosung
111Diverter timeout Triton
112Timeout waiting for leading edge at reject Triton
113"Timeout waiting for trailing edge at
reject "Triton
114Exit blocked during purge Triton
115Diverter timeout on purge Triton
116Motor Fault Triton
117Timeout waiting for note to divert Triton
118"Exit sensor blocked on start of
dispense or learn "Triton
119"Diverter in dispense position on
start of dispense or learn "Triton
120Reject Cassette not presentTriton
121Note cassette not present Triton
122Unexpected note at exit Triton
123Hardware Error Triton
124"Diverter moved to exit position
during reject purge "Triton
125Initial status check failed Triton
126"Diverter moved to reject position
during dispense "Triton
127Jam in TDM extension Triton
128"Error in reply from the dispenser
mechanism "Triton
129"No response from the dispenser
mechanism "Triton
13BGD done goodTriton
130"Command not acknowledged by
the dispenser mechanism "Triton
131"CTS (Clear To Send) line from the
dispenser is not active. "Triton
132"Status reports bad double detect in
last dispense "Triton
133"+5 VDC not present on carrier
detect "Triton
134"Exit blocked as reported by status
check "Triton
135Feed sensor blocked as reported by status check Triton
136Modem initialization failed Triton
137Print failure to JournalTriton
138"Printer failed while printing to the
receipt printer "Triton
139"Printer controller not responding to
commands "Triton
14BGD done badTriton
140"Time-out waiting for printer to be
ready "Triton
141"Paper jam reported by the
controller during status check. "Triton
142"Dispenser returns bad command
error. "Triton
143PTDF errorTriton
144"No reply from the electronic
journal. "Triton
145"Error in reply from the electronic
journal "Triton
146"No reply from command to
electronic journal "Triton
147"Error in reply from electronic
journal. "Triton
148Write to electronic journal failed Triton
149Read from electronic journal failed Triton
150Status command to journal failed Triton
151Electronic journal full Triton
152Electronic journal corrupt Triton
153Electronic journal mode Triton
154Unknown electronic journal status Triton
155"Electronic journal modify record
failure "Triton
156Cassette out of service. Triton
157"Erase command to electronic
journal failed "Triton
158"Format command to electronic
journal failed "Triton
159"Electronic journal test feature
failed "Triton
160"Electronic journal set featured
failed "Triton
161"Electronic journal clear feature
failed "Triton
162"Electronic Journal get serial
number failed "Triton
163Terminal did not answer. This is a Triton Connect error. Triton
164Terminal did not return call. Triton Connect error. Triton
165Electronic journal not present Triton
166Bad dispense Triton
167Reported low cash to Triton Connect Triton
168"Software download to terminal
failed. "Triton
17NO EOTTriton
18OverflowTriton
182Currency cassette low. Valid for SDD and GND mechanisms only. Triton
183Receipt printer paper is low Triton
184Journal printer paper lowTriton
185Telephone number not configured Triton
186Bill Size not configured Triton
187"Maximum withdrawal not
configured "Triton
188PIN working key not configured Triton
189Terminal ID not configured Triton
190PIN Master key not configured Triton
191Feed Failure Triton
192Communication error Triton
193The Baud rate setting for the EJ failedTriton
194"An Attempt to Dispense is made
the Cassettes are not Locked "Triton
195Receipt printer out of paper Triton
196Card reader error Triton
197Dispenser has detected a blocked stacker during a dispenseTriton
198Dispenser did not detect note going in stackerTriton
199Cash dispenser width errorsTriton
200Dispenser fed extra note into its stackerTriton
20001Unable to load a cassetteTranax
20001Unable to load a cassette.Genmega
2000100No cassetteTranax
2000100No cassetteHyosung
20002Low CashTranax
20002Low Cash.Genmega
2000200Note shortageTranax
2000200Note shortageHyosung
20003Reject Bin is FullTranax
20003Reject Bin full.Genmega
2000300Reject bin fullTranax
2000300Reject bin fullHyosung
20004Vault Door is OpenTranax
20004Vault Door is open.Genmega
2000400Vault Door is OpenTranax
2000400Vault door openHyosung
20005CDU setting errorTranax
2000500Cash Dispenser Unit data setting errorTranax
2000500Cash Dispenser Unit data setting errorHyosung
2001NO PRINTERVerifone
2001NO PRINTERTranax 2001 "No Printer-Check to see if the 24V LED on the side of the printer is on Try feeding paper into the printer Check the cable that runs from the printer port on the CPU to the printer for a loose connection or bent pins. Enter the Administrative menu Select $$$$ then BAL The printer will print the cashbox balance advance the paper and cut if not then try a new printer communications cable. If the cable doesn't work the contact WRG
20010Receipt Paper JamTranax
20010Receipt paper jam.Genmega
2001000Receipt Paper JamTranax
2001000Receipt paper jamHyosung
20011Print head is in up positionTranax
2001100Receipt Printer thermal head over heated.Hyosung
20012Receipt printer feed lever openTranax
20012Receipt feed lever open.Genmega
2001200Receipt printer feed plate openTranax
2001200Receipt printer feed plate openHyosung
20013Receipt paper is emptyTranax
20013Receipt paper empty.Genmega
2001300Out of receipt (Receipt paper empty)Tranax
2001300Out of receipt (Receipt paper empty)Hyosung
20014Thermal printer is overheatedTranax
20014Thermal printer is overheated.Genmega
2001400Receipt printer head overheated before printingTranax
2001400Receipt printer head overheated before printingHyosung
20015The feed lever of the recipt printer is open. It was detected that the feed lever was open before ther receipt printer started to operate.Tranax
20016Note Detected in Stacker(Shutter or Presenter type)Tranax
2001600No detected in stacker (shutter or presenterptetye)Tranax
2001600Note detected in stacker (shutter or presenter type)Hyosung
2002PRINTER PAPER JAMVerifone
2002PRINTER PAPER JAMTranax
2003PRINTER PAPER OUTVerifone
2003PRINTER PAPER OUTTranax
2003Printer out of paper (ATP printer only)WRG
2005Printer Head Up (ATP printer only)Tranax
2005Printer Head UP (ATP printer only)WRG
201Dispenser detected more than 6 errors in dispenseTriton
20101Receipt printer lever openedTranax
2010100Receipt printer lever openedTranax
2010100Receipt printer lever openedHyosung
20102Receipt printer head overheatedTranax
2010200Receipt printer head overheatedTranax
2010200Receipt printer head overheatedHyosung
20103Receipt paper jamTranax
2010300Receipt paper jamTranax
2010300Receipt paper jamHyosung
20104Receipt paper emptyTranax
2010400Receipt paper emptyTranax
2010400Receipt paper emptyHyosung
20105Receipt paper setting errorTranax
2010500Receipt paper setting errorTranax
2010500Receipt paper setting errorHyosung
20106Command is received while doing self-testTranax
2010600Command is received while doing self-testTranax
2010600Command is received while doing self-testHyosung
20107No receipt paperTranax
2010700No receipt paperTranax
2010700No receipt paperHyosung
20108Receipt paper cutting errorTranax
2010800Receipt paper cutting errorTranax
2010800Receipt paper cutting errorHyosung
20109No sensing black mark (dark sensor)Tranax
2010900No sensing black mark (dark sensor)Tranax
2010900No sensing black mark (dark sensor)Hyosung
2010AThe size of image print data is abnormalTranax
2010A00The size of image print data is abnormalTranax
2010A00The size of image print data is abnormalHyosung
202Dispenser is busyTriton
20215Sensor detects note in delivery path before CDU dispensesTranax
2021500Sensor detects note in delivery path before CDU dispensesTranax
2021500"Sensor detects note in delivery path before
CDU dispenses"Hyosung
203"SPED keypad is not replying to
main board "Triton
204Number of bills dispensed not equal to bills requestedTriton
205"SPED keypad reported tamper
condition "Triton
206SPED keypad could not perform a successful command within SPED_MAX_ATTEMPTS tries Triton
207SPED not detected Triton
208Dispenser did not reply after a dispense commandTriton
2080000Paper jammed at the exit of the slotTranax
20801Receipt printer lever openedTranax
2080100Receipt printer lever openedTranax
2080100Receipt printer lever openedHyosung
20802Receipt printer head overheatedTranax
2080200Receipt printer head overheatedTranax
2080200Receipt printer head overheatedHyosung
20803Receipt paper jamTranax
2080300Receipt paper jamTranax
2080300Receipt paper jamHyosung
20804Receipt paper emptyTranax
2080400Receipt paper empty 1.Replenish receipt paperTranax
2080400Receipt paper emptyHyosung
20805Receipt paper setting errorTranax
2080500Receipt paper setting errorTranax
2080500Receipt paper setting errorHyosung
20806Command is received while doing self-testTranax
2080600Command is received while doing self-testTranax
2080600Command is received while doing self-testHyosung
20807No receipt paperTranax
208070Receipt paper runs out of after printingHyosung
2080700No receipt paperTranax
2080700No receipt paperHyosung
20808Receipt paper cuttimg errorTranax
2080800Receipt paper cutting errorTranax
2080800Receipt paper cutting errorHyosung
20809No sensing black mark (dark sensor)Tranax
2080900No sensing black mark (dark sensor)Tranax
2080900No sensing black mark (dark sensor)Hyosung
2080AThe size of image print data is abnormalTranax
2080A00The size of image print data is abnormalTranax
2080A00The size of image print data is abnormalHyosung
2080B00Margin setting errorTranax
2080B00Margin setting errorHyosung
2080C00Paper jammed at the exit of the slotHyosung
2080D00Paper jammed in the pathTranax
2080D00Paper jammed in the pathHyosung
2080F00The firmware crashedTranax
2080F00The firmware crashedHyosung
209Check Number of notes delivered command failedTriton
210 Dispenser type unknown Triton
211The reply from the dispenser was invalidTriton
21315CS4 sensor detects note in delivery path befoe CDU dispensesTranax
2131500CS4 sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right before the reject bin.Tranax
2131500CS4 sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right before the reject bin.Hyosung
21A15CS1A sensor detects note in delivery path before CDU dispenses.Sensor is located along the delivery path right after where the note exits the 1st cassette.Tranax
21A1500CS1A sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right after where the note exits the 1st cassette.Tranax
21A1500CS1A sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right after where the note exits the 1st cassette.Hyosung
21B15CSB sensor detects note in delivery path before CDU dispensesSensor is located along the delivery path right after where the note exits the 1st cassette.Tranax
21B1500CSB sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right after where the note exits the 1st cassette.Tranax
21B1500"CSB sensor detects note in delivery path
before CDU dispenses. Sensor is located along the delivery path right after where the note exits the 1st cassette."Hyosung
231Card Reader Error (Smart Card) Triton
232Quad Port Module not Installed or not CommunicatingTriton
233Smart Card Reader not installed Triton
234Incompatible SPED versionTriton
235MAP stack overTriton
236Failed to make connection to TCP/IP host Triton
237TCP/IP device failed Triton
238Power failure during dispense Triton
239SPED serial number change Triton
240SPED Self Test Error Triton
241"SPED Warning: Self Test error low
battery "Triton
242Stuck key Triton
243"Unable to display user defined
surcharge screen "Triton
244"Min. partial dispense enabled with
no doc count "Triton
245"Min. partial dispense enabled with
no usable bills "Triton
246SPED password must be changed Triton
24A15CS3A sensor detects note in delivery path before CDU dispensesSensor is located along the delivery path right after where the note exits the 3rd cassette.Tranax
24A1500CS3A sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right after where the note exits the 3rd cassette.Tranax
24A1500CS3A sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right after where the note exits the 3rd cassette.Hyosung
24B15CS3B sensor detects note in delivery path before CDU dispensesSensor is located along the delivery path right after where the note exits the 3rd cassette.Tranax
24B1500CS3B sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right after where the note exits the 3rd cassette.Tranax
24B1500CS3B sensor detects note in delivery path before CDU dispenses. Sensor is located along the delivery path right after where the note exits the 3rd cassette.Hyosung
2DN0000Failed to connect communication between Receipt printer and SPTranax
2DN0000"Failed to connect communication between
Receipt printer and SP"Hyosung
2xx15Cash Dispenser detects bills prior to dispensingTranax
2xx15Cash Dispenser detects bills prior to dispensing.Genmega
2YY15"Sensor Detects note on delivery before CDU working YY : Sensor on delivery1A = NS2A 1B = NS2B 02 = -4A = NS3A 4B = NS3B 13 = NS4"Tranax
2YY1500Receipt paper jam.Hyosung
3BCD No AnswerTriton
300Successful Command Triton
3001REMOTE LOG INVerifone
3001REMOTE LOG INTranax
3002REMOTE BALANCE REQUESTVerifone
3002REMOTE BALANCE REQUESTTranax
3003REMOTE BALANCE SETVerifone
3003REMOTE BALANCE SETTranax
3005REMOTE SUM REQUESTVerifone
3005REMOTE SUM REQUESTTranax
3006REMOTE EVENT LOG REQUESTVerifone
3006REMOTE EVENT LOG REQUESTTranax
3007REMOTE JOURNAL LOG REQUESTVerifone
3007REMOTE JOURNAL LOG REQUESTTranax
3008REMOTE DATE SETVerifone
3008REMOTE DATE SETTranax
3009REMOTE TIME SETVerifone
3009REMOTE TIME SETTranax
301Low level in cassette Triton
3010REMOTE CNFG EDITVerifone
3010REMOTE CNFG EDITTranax
3011REMOTE CASH LOG REQUESTVerifone
3011REMOTE CASH LOG REQUESTTranax
3012REMOTE ERROR RESETVerifone
3012REMOTE ERROR RESETTranax
302Empty cassette Triton
303Lifts are down Triton
304Rejected notes Triton
305Diverter failure Triton
306Failure to feed. Triton
307Transmission Error Triton
308"Illegal command or command
sequence "Triton
309Jam in Note Qualifier Triton
310Cassette not properly installed. Triton
3100200Command Execution is fatalTranax
311Config record size invalid Triton
312No notes retracted Triton
313Cassette hopper map invalid Triton
314"Dispenser offline - cannot resolve
dispense count "Triton
315Reject vault not properly installed Triton
316Delivery failure. Triton
317Reject failure Triton
318Too many notes requested Triton
319Jam in note transport Triton
32Good operation Triton
320Reject cassette almost full Triton
321Cassette data corrupted Triton
322Main motor failure Triton
323"Dispenser offline - Dispense count
check error "Triton
324Reserved for warning status Triton
325Note qualifier faulty Triton
326Note feed sensor failure Triton
327Shutter failure Triton
329Notes in delivery throat Triton
33Note jammed between DDM and Exit sensor Triton
330Communication timeout Triton
332Cassettes may have been changed Triton
333Reject vault full Triton
339Error in throat Triton
34Mis-tracked note at feed Triton
343Sensor error or sensor covered Triton
348Dispenser internal error. Triton
349Cassette lock faulty Triton
35Mistracked note at double detect. Triton
350Jam in note stacker Triton
351Module needs service Triton
353No message to resend Triton
356Error in note transport Triton
357"Triton - Dispenser data size error - Wrong dispenser setting in programming
Genmega - C005E - Reject Gate Solenoid did not activate to reject bills"Triton
358Dispenser device read error Triton
359Dispenser device record error Triton
36Mistracked note at exit. Triton
360Dispenser invalid return ID Triton
361Dispenser sequence error Triton
362Dispenser device write error Triton
363Dispenser device not found Triton
364Dispenser device offline Triton
365Dispenser BCC error Triton
366Dispenser cassettes disabled Triton
367Dispenser communication error. Triton
368Dispenser cannot dispense the request Triton
369Dispenser device reset Triton
37Too long at exit. Triton
370Dispenser - EOT error Triton
371Dispenser com error header-trailer Triton
372Dispenser item value error Triton
373Dispenser machine not opened Triton
374Dispenser rejected check Triton
375Dispenser invalid request Triton
376Dispenser multiple device error Triton
377Dispenser device error Triton
378Dispenser cassette low Triton
379Dispenser unknown error code Triton
38Blocked exit Triton
380Dispenser setup incomplete Triton
381Dispenser cassette invalid Triton
382Dispenser cassettes disabled (ALL) Triton
383Dispense cassettes low (ALL) Triton
384Dispenser cassettes empty (ALL) Triton
385"Dispenser offline no reject vault and no
hoppers "Triton
386Dispenser offline - no hoppers Triton
387"Dispenser offline - error-validating
configuration "Triton
388Dispenser offline - NMD require Reject Vault and at least one cassette Triton
389"Dispenser offline. Detected offline error
check op state "Triton
39Too many notes Triton
390Dispenser offline - storing configurationTriton
391Dispenser sensor failure 2 Triton
392Error in last dispense Triton
393Error in double detect 2 Triton
394Purge failed upon power-up Triton
395Multiple cassette of the same type Triton
396"Dispenser offline � found no reject
bin "Triton
397NMD 50 Dispense Status Unknown at BootTriton
4Error in Modem DataTriton
400Exchange Rate not ConfiguredTriton
4000Error of being removed 2nd cassette before separate rejectionHyosung
40000Cash Dispenser(CDU) received the undefined command from AP softwareTranax
40000Receive undefined command.Hyosung
4000000Cash Dispenser(CDU) received the undefined command from AP softwareTranax
4000000Cash Dispenser(CDU) received the undefined command from AP softwareHyosung
4000600Error of CS 2 CS13 sensor during initializationTranax
4000700Something is detected on CS12 sensor during dispensing bills or initialization.Tranax
4000800Something is detected on CS14 sensor during dispensing bills or initialization.-Tranax
4001NO DISPENSERVerifone
4001NO DISPENSERTranax
4001No dispenserWRG
40011Notes are detected on tray(CS2 Sensor) before dispensingTranax
4001100Detecting CS2 Dark (Front Access Type:Reject box is opened.)Tranax
4001100"Detecting CS2 / LS3 Dark
(Front Access Type : Reject box is opened.)"Hyosung
40014CS4A sensor detects note in delivery path before/after CDU dispensesTranax
40014#NAME?Hyosung
4001400CS4A sensor detects note in delivery path before/after CDU dispensesTranax
4001400CS4A / LS9 sensor detects note in delivery path before/after CDU dispensesHyosung
40015CS2 or CS4A sensor detects note in delivery path before/after CDU dispensesTranax
4001500CS2 or CS4A sensor detects note in delivery path before/after CDU dispensesTranax
4001500CS2 or CS4A sensor detects note in delivery path before/after CDU dispensesHyosung
40018CS4B sensor detects note in delivery path before/after CDU dispensesTranax
40018#NAME?Hyosung
4001800CS4B sensor detects note in delivery path before/after CDU dispensesTranax
4001800CS4B sensor detects note in delivery path before/after CDU dispensesHyosung
40019CS2 or CS4B sensor detects note in delivery path before/after CDU dispensesTranax
4001900CS2 or CS4B sensor detects note in delivery path before/after CDU dispensesTranax
4001900CS2 or CS4B sensor detects note in delivery path before/after CDU dispensesHyosung
4001CCS4A or CS4B sensor detects note in delivery path before/after CDU dispensesTranax
4001C#NAME?Hyosung
4001C00CS4A or CS4B sensor detects note in delivery path before/after CDU dispensesTranax
4001C00CS4A or CS4B sensor detects note in delivery path before/after CDU dispensesHyosung
4001D"CS2 CS4A or CS4B sensor detects note in delivery path before/after CDU dispenses"Tranax
4001D00CS2 CS4A or CS4B sensor detects note in delivery path before/after CDU dispensesTranax
4001D00"CS2 CS4A or CS4B sensor detects note in delivery path before/after CDU dispenses"Hyosung
4002DISPENSER EXIT SENSOR BLOCKEDVerifone
4002DISPENSER EXIT SENSOR BLOCKEDTranax
4002Dispenser exit sensor blockedWRG
40021CS1A sensor detects note in delivery path before/after CDU dispensesTranax
40021"Detect CS1A after initialization / Detect CS1A
before dispensing."Hyosung
4002100CS1A sensor detects note in delivery path before/after CDU dispensesTranax
4002100CS1A / LS1 sensor detects note in delivery path before/after CDU dispensesHyosung
40022CS1B sensor detects note in delivery path before/after CDU dispensesTranax
40022"Detect CS1B after initialization / Detect CS1B
before dispensing."Hyosung
4002200CS1B sensor detects note in delivery path before/after CDU dispensesTranax
4002200CS1B sensor detects note in delivery path before/after CDU dispensesHyosung
40023CS1A or CS1B sensor detects note in delivery path before/after CDU dispensesTranax
40023"Detect CS1A & CS1B after initialization / Detect
CS1A & CS1B before dispensing."Hyosung
4002300CS1A or CS1B sensor detects note in delivery path before/after CDU dispensesTranax
4002300CS1A or CS1B sensor detects note in delivery path before/after CDU dispensesHyosung
40028CS13 sensor detects note in delivery path before/after CDU dispensesTranax
40028Detect CS13 after initialization / Detect CS13 before dispensing.Hyosung
4002800CS13 sensor detects note in delivery path before/after CDU dispensesTranax
4002800CS13 sensor detects note in delivery path before/after CDU dispensesHyosung
40029CS1A or CS13 sensor detects note in delivery path before/after CDU dispensesTranax
40029"Detect CS13 & CS1A after initialization / Detect
CS13 & CS1A before dispensing."Hyosung
4002900CS1A or CS13 sensor detects note in delivery path before/after CDU dispensesTranax
4002900CS1A or CS13 sensor detects note in delivery path before/after CDU dispensesHyosung
4002ACS1B or CS13 sensor detects note in delivery path before/after CDU dispensesTranax
4002A"Detect CS13 & CS1B after initialization / Detect
CS13 & CS1B before dispensing."Hyosung
4002A00CS1B or CS13 sensor detects note in delivery path before/after CDU dispensesTranax
4002A00CS1B or CS13 sensor detects note in delivery path before/after CDU dispensesHyosung
4002B"CS1A CS1B or CS13 sensor detects note in delivery path before/after CDU dispenses"Tranax
4002B"Detect CS13 & CS1A & CS1B after initialization
/ Detect CS13 & CS1A & CS1B before dispensing."Hyosung
4002B00CS1A CS1B or CS13 sensor detects note in delivery path before/after CDU dispensesTranax
4002B00"CS1A CS1B or CS13 sensor detects note in delivery path before/after CDU dispenses"Hyosung
4003DISPENSER FEED SENSOR BLOCKEDVerifone
4003DISPENSER FEED SENSOR BLOCKEDTranax
4003Dispenser feed sensor blockedWRG
40030Failed in checking the main motor echoTranax
40030"(INITIAL / DISPENSE) Motor Constant Speed
Error"Hyosung
4003000Failed in checking the main motor echoTranax
4003000Failed in checking the main motor echoHyosung
40031Failed in checking the reject gate solenoid echoTranax
40031(INITIAL / DISPENSE) SOLENOID ECHO ErrorHyosung
4003100Failed in checking the reject gate solenoid echoTranax
4003100Failed in checking the reject gate solenoid echoHyosung
40032Failed in checking the present gate solenoid echoTranax
4003200Failed in checking the present gate solenoid echoTranax
4003200Failed in checking the present gate solenoid echoHyosung
40033Check sum error (No information is set)Tranax
4003300Check sum error (No information is set)Tranax
4003300Check sum error (No information is set)Hyosung
40034Error of two sheets detecting sensor(CS5_1)Tranax
4003400Error of two sheets detecting sensor(CS5_1) for initializingTranax
4003400"Error of two sheets detecting sensor(CS5_1)
for initializing"Hyosung
40036"Error of CS 2 CS13 sensor during initialization"Tranax
40036Detect CS13 before initialization.Hyosung
4003600Error of CS 2 CS13 sensor during initializationTranax
4003600"Error of CS 2 CS13 / LS2 sensor during initialization"Hyosung
40037Error of 2 sheets detecting sensor(CS5_1/CS5_2)Tranax
4003700Error of 2 sheets detecting sensor (CS5_1 / CS5_2) for dispensingTranax
4003700Error of 2 sheets detecting sensor (CS5_1 / CS5_2) for dispensingHyosung
40038Error in checking SRAMTranax
4003800Error in checking SRAMTranax
4003800Error in checking SRAMHyosung
40039Gate operation sensor (CS3) errorTranax
40039"(INITIAL / DISPENSE) Solenoid Operation
Error before motor activation"Hyosung
4003900Gate operation sensor (CS3) error before initial recoveryTranax
4003900Gate operation sensor (CS3 / LS8) error before initial recoveryHyosung
4003AWhen more than 5 sheets of cash dispensingis required during a testTranax
4003A00When more than 5 sheets of cash dispensing is required during a testTranax
4003A00When more than 5 sheets of cash dispensing is required during a testHyosung
4003BWhen CS15A or CS 15B sensor is detected as dark after initial recoveryTranax
4003B00When CS15A or CS 15B sensor is detected as dark after initial recoveryTranax
4003B00When CS15A or CS 15B sensor is detected as dark after initial recoveryHyosung
4004DISPENSER FEED FAILUREVerifone
4004DISPENSER FEED FAILURETranax
4004Dispenser feed failureWRG
4004Error of being removed 2nd cassette before separate rejectionHyosung
40040Cassette is removed during dispensingTranax
40040(DISPENSE) Reboot 5 or more times due to cassette separationHyosung
4004000Cassette is removed during dispensingTranax
4004000Cassette is removed during dispensingHyosung
40041Error if re-driving is over 5 times during separated rejectionTranax
40041(DISPENSE) Reboot 12 or more timesHyosung
4004100Error if re-driving is over 5 times during separated rejectionTranax
4004100Error if re-driving is over 5 times during separated rejectionHyosung
40042In case the number of notes detected outlet sensor(CS13) is less thanthe number of required notesTranax
40042(DISPENSE) The dispensed number of notes is less than requested.Hyosung
4004200In case the number of notes detected outlet sensor(CS13) is less thanthe number of required notesTranax
4004200In case the number of notes detected outlet sensor(CS13 / LS2) is less than the number of required notesHyosung
40043Error if total reject is more than 20 sheetsTranax
40043(DISPENSE) Reject more than 40 sheets.Hyosung
4004300Error if total reject is more than 20 sheetsTranax
4004300Error if total reject is more than 20 sheetsHyosung
40044Error if continuous 5 times are rejectedTranax
4004400Error if continuous 5 times are rejectedTranax
4004400Error if continuous 5 times are rejectedHyosung
40045In case the number of notes detected outlet sensor(CS13) is more than required notes.Tranax
40045(DISPENSE) The dispensed number of notes is more than requested during/after operationHyosung
4004500In case the number of notes detected outlet sensor(CS13) is more than required notesTranax
4004500In case the number of notes detected outlet sensor(CS13 / LS2) is more than required notesHyosung
40046Program error(Separated rejection)Tranax
4004600Program error(Separated rejection)Tranax
4004600Program error(Separated rejection)Hyosung
400471 cassette misfeed error (Separated rejection)Tranax
40047(DISPENSE) Reboot 5 or more times due to miss pick upHyosung
40047001 cassette mis-feed error (Separated rejection)Tranax
40047001 cassette mis-feed error (Separated rejection)Hyosung
40048Mismatched number of bills errorTranax
4004800Error if the number of dispensed notes is not matched to the requestedTranax
4004800Error if the number of dispensed notes is not matched to the requestedHyosung
40049Error to dispense 0 sheets to be required(Separated rejection)Tranax
40049(DISPENSE) Received the number of requirement by �0�.Hyosung
4004900Error to dispense 0 sheets to be required (Separated rejectionTranax
4004900"Error to dispense 0 sheets to be required
(Separated rejection"Hyosung
4004AError of note jam (Separated rejection)Tranax
4004A(DISPENSE) Jam during dispensing.Hyosung
4004A00Error of note jam (Separated rejection)Tranax
4004A00Error of note jam (Separated rejection)Hyosung
4004B"Continuous 3 times error if note is long (once tried twice retried)=>Separated rejection"Tranax
4004B00Continuous 3 times error if note is long(once tried twice retried)=>Separated rejectionTranax
4004B00"Continuous 3 times error if note is long
(once tried twice retried)=>Separated rejection"Hyosung
4004C"In case the number of notes detected outlet sensor(CS13) is more than that of notesdetected on CS1AB sensor"Tranax
4004C00In case the number of notes detected outlet sensor(CS13) is more than that of notes detected on CS1AB sensorTranax
4004C00"In case the number of notes detected outlet sensor(CS13/ LS2) is more than that of notes
detected on CS1AB sensor"Hyosung
4004DError of being removed 1st cassette before separate rejectionTranax
4004D(DISPENSE) Cassette separation before operation.Hyosung
4004D00Error of being removed 1st cassette before separate rejectionTranax
4004D00Error of being removed 1st cassette before separate rejectionHyosung
4004EError of being removed 2nd cassette before separate rejectionTranax
4004Error of being removed 2nd cassette before separate rejectionHyosung
4005"REVERSAL SUCCESSFUL"Verifone
4005"REVERSAL SUCCESSFUL"Tranax
4005Reversal SuccessfulWRG
40051Received a request for over 150 notes dispensing on the Cash Dispenser from the upper unit.Tranax
40051(DISPENSE) Received the required number of notes 150 or more.Hyosung
4005100Received a request for over 150 notes dispensing on the Cash Dispenser from the upper unit.Tranax
4005100Received a request for over 150 notes dispensing on the Cash Dispenser from the upper unit.Hyosung
40052"The remaining notes at the sensor in front of the CST after dispense operation (CS1A CS1B)"Tranax
4005200The remaining notes at the sensor in front of the CST after dispense operation (CS1A CS1B)Tranax
4005200"The remaining notes at the sensor in front of the CST after dispense operation (CS1A CS1B)"Hyosung
40053Error for the double note detection during separation.Tranax
4005300Error for the double note detection during separation.Tranax
4005300Error for the double note detection during separation.Hyosung
40054Cash Dispenser EP Program Error during dispense operation (failed table search)Tranax
4005400Cash Dispenser EP Program Error during dispense operation (failed table search)Tranax
4005400Cash Dispenser EP Program Error during dispense operation (failed table search)Hyosung
40055Timeout due to note�s length error passed through the CS13 during dispense operationTranax
40055(DISPENSE) Detect CS13 during constant speed of motor / CS13 Jam during dispensing.Hyosung
4005500Timeout due to notes length error passed through the CS13 during dispense operationTranax
4005500Timeout due to note�s length error passed through the CS13 / LS2 during dispense operationHyosung
40056Abnormal operation of the gate solenoid during dispense operation.Tranax
40056(DISPENSE) Solenoid Error during dispensing.Hyosung
4005600Abnormal operation of the gate solenoid during dispense operation.Tranax
4005600Abnormal operation of the gate solenoid during dispense operation.Hyosung
4005700Cash dispenser configuration errorTranax
4005700Cash dispenser configuration errorHyosung
40058Retract box position error during command reserved operationTranax
4005800Retract box position error during command reserved operationTranax
4005800Retract box position error during command reserved operationHyosung
40059Initial jam time errorTranax
4005900Initial jam time errorTranax
4005900Initial jam time errorHyosung
4005B2 Cassette Miss Feed Error (Fail to reject bill separately.)Tranax
4005B002 Cassette Miss Feed Error (Fail to reject bill separately.)Tranax
4005B002 Cassette Miss Feed Error (Fail to reject bill separately.)Hyosung
4005CRJ BIN2 (collection box) bill detection error (CS14) ? Initial U.S. type rear deviceTranax
4005DContinuously detected 2 notes for three times or more during dispense operationTranax
4005D00Continuously detected 2 notes for three times or more during dispense operationTranax
4005D00Continuously detected 2 notes for three times or more during dispense operationHyosung
4006"REVERSAL FAILED"Verifone
4006"REVERSAL FAILED"Tranax
4006Reversal FailedWRG
40060Something is detected in C31AB sensor before dispensing bills from 3rd cassette.Tranax
4006000Something is detected in C31AB sensor before dispensing bills from 3rd cassette.Tranax
4006000Something is detected in C31AB sensor before dispensing bills from 3rd cassette.Hyosung
40061Something is detected in C31AB sensor before dispensing bills.Tranax
4006100Something is detected in C31AB sensor before dispensing bills.Tranax
4006100Something is detected in C31AB sensor before dispensing bills.Hyosung
40062Bills are remained in CS1AB sensor after dispensing bills.Tranax
4006200Bills are remained in CS1AB sensor after dispensing bills.Tranax
4006200Bills are remained in CS1AB sensor after dispensing bills.Hyosung
40063Bills are remained in CS31AB sensor after dispensing billsTranax
4006300Bills are remained in CS31AB sensor after dispensing billsTranax
4006300Bills are remained in CS31AB sensor after dispensing billsHyosung
4006ACS15AB ~ CS13 Time out(Jam) during dispensing bills from second cassette.Tranax
4006A00CS15AB - CS13 Time out(Jam) during dispensing bills from second cassette.Tranax
4006A00CS15AB ~ CS13 Time out(Jam) during dispensing bills from second cassette.Hyosung
4006B"Something is detected on CS31A CS31B sensor during initialization"Tranax
4006B00Something is detected on CS31A CS31B sensor during initializationTranax
4006B00"Something is detected on CS31A CS31B
sensor during initialization"Hyosung
4007Mistracked note at feed sensor (dispenser)Tranax
4007Mistracked note at feed sensor (dispenser)- (bill arrived at the feed sensor while a bill was still at the double detect) check the bills in the cassette (may be worn or sticking together)WRG
40070Something is detected on CS41AB sensor before dispensing bills from fourth cassette.Tranax
4007000Something is detected on CS41AB sensor before dispensing bills from fourth cassette.Tranax
4007000Something is detected on CS41AB sensor before dispensing bills from fourth cassette.Hyosung
40072Something is detected on CS41AB sensor during dispensing bills.Tranax
4007200Something is detected on CS41AB sensor during dispensing bills.Tranax
4007200Something is detected on CS41AB sensor during dispensing bills.Hyosung
40073Bills is remained in CS41AB sensor after dispensing bills.Tranax
4007300Bills is remained in CS41AB sensor after dispensing bills.Tranax
4007300Bills is remained in CS41AB sensor after dispensing bills.Hyosung
4007ACS31AB ~ CS13 Time out (Jam) during dispensing bills from fourth cassette.Tranax
4007A00CS31AB - CS13 Time out (Jam) during dispensing bills from fourth cassette.Tranax
4007A00CS31AB ~ CS13 Time out (Jam) during dispensing bills from fourth cassette.Hyosung
4007B"Something is detected on CS41A CS41B sensor in initialization"Tranax
4007B00Something is detected on CS41A CS41B sensor in initializationTranax
4007B00"Something is detected on CS41A CS41B
sensor in initialization"Hyosung
4007CMissfeed error in 4th cassetteTranax
4007C00Missfeed error in 4th cassetteTranax
4007C00Missfeed error in 4th cassetteHyosung
4007DTrying to dispense bills from 4th cassette but the 4th cassette doesn't installed.Tranax
4007D00Trying to dispense bills from 4th cassette but the 4th cassette doesnt installed.Tranax
4007D00Trying to dispense bills from 4th cassette but the 4th cassette doesn't installed.Hyosung
4008Mistracked note at the double detect (dispenser)WRG
40080Something is detected on CS15AB sensor before dispensing operationTranax
4008000Something is detected on CS15AB sensor before dispensing operationTranax
4008000Something is detected on CS15AB sensor before dispensing operationHyosung
40081Something is detected in C15AB sensor during dispensing operationTranax
4008100Something is detected in C15AB sensor during dispensing operationTranax
4008100Something is detected in C15AB sensor during dispensing operationHyosung
40082Bill is remained in CS15AB sensor after dispensing operationTranax
4008200Bill is remained in CS15AB sensor after dispensing operationTranax
4008200Bill is remained in CS15AB sensor after dispensing operationHyosung
40088(DISPENSE) Dispense the notes on the state of unsupported denomination setting.Hyosung
4008FCS13 sensor detects the notes with holeTranax
4008F00CS13 sensor detects a bill with hole during dispensingTranax
4008F00CS13 sensor detects a bill with hole during dispensingHyosung
4009Mistracked note at exit (dispenser)Tranax
4009Mistracked note at exit (dispenser)- (bill arrived at the exit sensor without being seen by the other sensors)WRG
40090Decryption Error / Key ErrorHyosung
40091Receive CMD except certification on the status of non-certification.Hyosung
40092Encryption Chip Communication ErrorHyosung
40093"0xC1 Command Execution Error (Certification
Fail)"Hyosung
40094"0xC2 Command Execution Error (Certification
Fail)"Hyosung
4009ACS31AB~CS13 Time out(Jam) during dispensing from 3rd cassette.Tranax
4009A00CS31AB-0513 Time out(Jam) during dispensing from 3rd cassette.Tranax
4009A00CS31AB~CS13 Time out(Jam) during dispensing from 3rd cassette.Hyosung
4009DTrying to dispense bills from 3rd cassette but the 3rd cassette doesn't installed.Tranax
4009D00Trying to dispense bills from 3rd cassette but the 3rd cassette doesnt installed.Tranax
4009D00Trying to dispense bills from 3rd cassette but the 3rd cassette doesn't installed.Hyosung
4009F3 cassette miss feed errorTranax
4009F003 cassette miss feed errorTranax
4009F003 cassette miss feed errorHyosung
400ACSomething is detected on CS2 sensor after dispense operationTranax
400AC00Something is detected on CS2 sensor after dispense operationTranax
400AC00Something is detected on CS2 sensor after dispense operationHyosung
400BCCommunication error - Command Length doesn't match.Tranax
400BC00Communication error - Command Length doesnt match.Tranax
400BC00Communication error - Command Length doesn't match.Hyosung
400BD(Set CDU Info) CDU Type Setting ErrorHyosung
400BE"Bill pickup sensor(CS1 CS15) recognized has a hole and CS4 sensor detects it or CS4 snesor detects the gap too close"Tranax
400BE(DISPENSE) Jam on the transport during operation (CS4 A/B Dark)Hyosung
400BE00Bill pickup sensor(CS1 CS15) recognized has a hole and CS4 sensor detects it or CS4 snesor detects the gap too closeTranax
400BE00"Bill pickup sensor(CS1 CS15) recognized has
a hole and CS4 sensor detects it or CS4 snesor detects the gap too close"Hyosung
400BF"(Initialize Dispense) No Encoder Signal 150ms or more during operation."Hyosung
400C100Cassette Jam during dispense operation(1 CST Encoder Error).Tranax
400C100"Cassette Jam during dispense operation
(1 CST Encoder Error)."Hyosung
400C200Cassette Jam during dispense operation(2 CST Encoder Error).Tranax
400C200"Cassette Jam during dispense operation
(2 CST Encoder Error)."Hyosung
400C300Cassette Jam during dispense operation(3 CST Encoder Error).Tranax
400C300"Cassette Jam during dispense operation
(3 CST Encoder Error)."Hyosung
400C400Cassette Jam during dispense operation(4 CST Encoder Error).Tranax
400C400"Cassette Jam during dispense operation
(4 CST Encoder Error)."Hyosung
400C6Detect CS13 during initialization.Hyosung
400C600"Error of CS 2 CS13 sensor during initialization"Hyosung
400C7Something is detected on CS12 sensor during dispensing bills or initialization.-MB TTWTranax
400C700CS12 sensor is detected as dark during initialize or dispenseTranax
400C700Something is detected on CS12 sensor during dispensing bills or initialization.Hyosung
400C8Something is detected on CS14 sensor during dispensing bills or initialization.-MB TTWTranax
400C800CS14 sensor is detected as dark during initialize or dispenseTranax
400C800Something is detected on CS14 sensor during dispensing bills or initialization.Hyosung
400C9Something is detected on CS14 sensor after dispense operationTranax
400C900Something is detected on CS14 sensor after dispense operationTranax
400C900Something is detected on CS14 sensor after dispense operationHyosung
400CCBill is remained on the sensor in front of cassette during resetting.Tranax
400CC"(DISPENSE) Detect CS1A CS1B just before reset."Hyosung
400CC00Bill is remained on the sensor in front of cassette during resetting.Tranax
400CC00Bill is remained on the sensor in front of cassette during resetting.Hyosung
400D0"Bills are passed on CS13~CS12 sensor -Timeout[Jam] MB TTW"Tranax
400D000Bills are passed on CS13-0512 sensor - Timeout[Jam]Tranax
400D000Bills are passed on CS13~CS12 sensor - Timeout[Jam].Hyosung
400D1"Bills are passed on CS12~CS14 sensor -Timeout[Jam] MB TTW"Tranax
400D100Bills are passed on CS12-CS14 sensor - Timeout[Jam].Tranax
400D100Bills are passed on CS12~CS14 sensor - Timeout[Jam].Hyosung
400D7DIP Switch Setting ErrorHyosung
400FFBill jamTranax
400FF00Bill jamTranax
400FF00Bill jamHyosung
401Cassette Currency Configuration ErrorTriton
4010Note too long at exit (dispenser)Tranax
4010Note too long at exit (dispenser)- (exit sensor blocked for longer than allowed). Check the ATM to make sure that the bills are not hanging up at the exit. WRG
4011Too many notes (dispenser)Tranax
4011Too many notes (dispenser)- (more bills than requested have passed the exit sensor)WRG
4012Timing wheel error (dispenser)Tranax
4012"Timing wheel error (dispenser)- (transport motor has stalled). Check the dispenser for jammed bills check the vault door switch and wiring Check the power supply. Enter the Admin menu with vault door closed Select $$$$ Select TEST. The dispenser should pull one bill from the cassette and put it in the reject compartment; the display should flash Test Successful. If the test was successful press CANCEL until the Welcome Screen appears. "WRG
4013Double detect error (Mini Mech dispenser)Tranax
4013Bad roller profile error (SDD dispenser)- Noise is seen on the double detect baseline signal in-between billsWRG
4014Diverter error (Mini Mech and Puloon dispensers)Tranax
4014Diverter error- (Mini mech and Puloon dispensers)- (The diverter has failed to deliver a bill. The bill may have been sent to the reject bin.) Check for objects blocking the bill diverter. WRG
4015Exit quantified-wrong count (dispenser)Tranax
4015"Exit quantified-wrong count (dispenser)- (The count at the exit sensor disagrees with the other sensors-the exit count has been calculated). Enter the Admin menu 9make sure that the vault door is closed) Select $$$$ select TEST the dispenser should pull one (1) bill from the cassette and put it in the reject compartment; the display should flash Test Successful if so press CANCEL until the Welcome Screen appears. If the problem persists contact WRG. "WRG
4016Note missing at the double detect (dispenser)Tranax
4016"Note missing at the double detect (dispenser)- (the double detect failed to detect a bill which has been identified by the feed sensor.) Check for a jammed bill. If no bill found contact WRG."WRG
4017"Reject rate exceeded (dispenser)- More that eight reject events have occurred during the current operation or the overall reject rate exceeds 10%. Check the quality of the bills. If problem persists contact WRG."WRG
4018"Interference recovery (dispenser)- (The operation of the microprocessor was interrupted but successful recovery was achieved) If problem persists contact WRG"WRG
4019Suspect exit accountancy (dispenser)Tranax
4019Suspect exit accountancy (dispenser)- The dispenser cannot guarantee the exit count; error routines have been invoked to finish the operation) During a test dispense this implies that the exit sensor is not functioning. Contact WRG.WRG
4020RAM error (dispenser)Tranax
4020RAM error (dispenser)- The dispenser has identified an error in its random access memory; no operation is permitted. Contact WRGWRG
4021EPROM error (dispenser)Tranax
4021"EPROM error (dispenser)- (The dispenser has identified an error in its program memory no operation is permitted) Contact WRG"WRG
4022Operation timeout (normally caused by a feed failure)Tranax
4022"Operation timeout (normally caused by a feed failure)- (The current transaction- dispense test dispense or purge- has exceeded its timeout period and has terminated) Enter the Admin Menu (make sure that the vault door is closed). Select $$$$ select TEST Make sure the dispenser pulls a bill from the cassette and puts it in the reject bin (should say test successful) if so press CANCEL until Welcome Screen appears. "WRG
4023Ram Corruption-Inter que error (dispenser)Tranax
4023"Ram Corruption-Inter que error (dispenser)- (The internal counters are corrupted. The operation is terminated and the exit count cannot be guaranteed). Check for bill jams in the dispenser If no bill jams were found then Enter the Admin Menu (ensure vault door is closed) Select $$$$ Select TEST. The dispenser should put a bill in the reject tray. If so press CANCEL until the Welcome Screen appears. "WRG
4024Link error (dispenser)Tranax
4024Link Error (dispenser)- (The option selection links have changed- no operation is possible) Replace the dispenserWRG
4025Invalid command issued to the dispenserTranax
4025Invalid command to the dispenser- No user action is requiredWRG
4026Reject Tray Open (Puloon dispenser)Tranax
4026Reject Tray Open (Puloon Dispenser)- The reject bin is open or the switch needs to be adjusted. Contact WRG if problem persistsWRG
4027No cassette (Puloon)Tranax
4027"No cassette (Puloon)- Open the vault and make sure that the cassette is fully inserted into the dispenser close and secure the vault door. Enter the Admin Menu select $$$$ Select TEST the dispenser should pick a bill and put it in the reject tray. If successful press CANCEL until the Welcome Screen appears."WRG
4028"Jam at the DIV sensor (Puloon)- Check for a bill jam between the feed rollers and the top. After clearing the jam the run a dispenser test to clear the error. If test fails more than three times contact WRG. "WRG
4029Counting Error (between the DIV and EJT sensors) (Puloon)Tranax
4029"Counting Error (between the DIV and EJT sensors) (Puloon)- Check for a bill jam just before and after the vertical to horizontal transition. After clearing the bill jam then run a dispenser test in the cash menu. If successful press CANCEL until Welcome screen appears if not contact WRG."WRG
4030"Counting Error (between the EJT and Exit sensors) (Puloon)- open the front of the bill path and check for a bill jam after clearing the bill jam then run a dispenser test in the cash menu. If successful then exit to the welcome screen. If not call WRG."WRG
4031"Time out (from the DIV sensor to the EJT sensor) (Puloon)- Check for a bill jam just before and after the vertical to horizontal transition. After clearing the jam then run a dispenser test in the cash menu. If successful cancel out to the welcome screen. If not then contact WRG."WRG
4032Potentiometer error (F50)Tranax
4032Potentiometer error (F50)- Contact WRGWRG
4101No dispenser response (NDR)Tranax
4101"no dispenser response (NDR)- Test the printer: if the printer doesn't work check the power supply. Make sure the communications cable between the dispenser port on the CPU and the dispenser are connected securely and not damaged in any way. Check the power supply cable is secure on the back of the dispenser. Check to LED on the back of the dispenser (should be on). If the ATM has a Puloon dispenser the vault door switch MUST be held in. Run a dispenser test if successful exit to the Welcome Screen. If not the replace the communications cable and retest the dispenser. If the problem persists then contact WRG. "WRG
42Transport errorTriton
44Bad Roller Profile Triton
45Diverter error Triton
46Exit quantified Triton
47Note missing at double detect Triton
48Reject rate exceeded. Triton
49Too few notes dispensed Channel 1 Triton
4DN00Cash Dispenser communication failure during sending command to cash dispenserTranax
4DN0000Cash Dispenser communication failure during sending command to cash dispenserTranax
4DN0000Cash Dispenser communication failure during sending command to cash dispenserHyosung
4DN01Cash Dispenser communication failure during sending command to cash dispenserTranax
4DN0100Cash Dispenser communication failure during receiving command to cash dispenserTranax
4DN0100Cash Dispenser communication failure during receiving command to cash dispenserHyosung
4DN8100Communication error of ShutterTranax
4DN8100Communication error of ShutterHyosung
5Connect 1200 Baud then lost carrier or connection. Host hung up.Triton
50Interference recovery Triton
500SPED Read Error Triton
5001JOURNAL LOG REACHING MAXIMUM POINTVerifone
5001JOURNAL LOG REACHING MAXIMUM POINTTranax
5001" Journal log is reaching the maximum point (electronic journal almost full)- goto RPTS select JRNL then select NEW"WRG
5002JOURNAL LOG FULLVerifone
5002JOURNAL LOG FULLTranax
5002"Journal log full (electronic journal full)- From the Admin menu select RPTS Select JRNL Select NEW. If error still exists after clearing the journal then run a dispenser test. Once successful press Cancel until the welcome screen appears. "WRG
5003LOW CASHVerifone
5003LOW CASHTranax
5003"Low cash (balance in machine is a t or below the bills size i.e. $20)- add cash to ATM"WRG
5004LOW CASH WARNINGVerifone
5004LOW CASH WARNINGTranax
5004"Low cash warning (user preset amount calls the pager if option set)- add cash to ATM"WRG
5005SURCHARGE DETAILVerifone
5005SURCHARGE DETAILTranax
5005Surcharge denial (customer denied surcharge and canceled transaction)WRG
5006INTERRUPTED TRANSACTIONVerifone
5006INTERRUPTED TRANSACTIONTranax
5006"Interrupted transaction- Possible phone line trouble (check the phone line) if problem persists contact WRG"WRG
501SPED invalid return record Triton
502SPED read type error Triton
503SPED invalid command Triton
504SPED invalid return ID Triton
505SPED device busy Triton
506 SPED invalid request Triton
507SPED sequence error Triton
508SPED LRC error Triton
509SPED no data Triton
51Accountancy error Triton
510SPED invalid message ID Triton
511SPED Data overflow Triton
512SPED device idle Triton
513SPED device offline Triton
514SPED device bit stuck Triton
515SPED device attention stuck Triton
516SPED device no attention Triton
517SPED device timeout Triton
518SPED command sequence error Triton
519SPED invalid command data Triton
52RAM error Triton
520SPED device reset Triton
521SPED clear key Triton
522EJ error Triton
523EJ data size error Triton
524EJ bad command Triton
525EJ invalid ID Triton
526EJ device busy Triton
527EJ invalid request Triton
528EJ sequence error Triton
529EJ device offline Triton
53EPROM error Triton
530EJ EXT error Triton
5300No Savings AccountHyosung
531EJ SOH error Triton
532EJ STX error Triton
533EJ BCC error Triton
534EJ device reset Triton
535Card Reader - Data size error Triton
536Card Reader - Device read error Triton
537Card Reader - Invalid Record Triton
538Card Reader - Reader type error Triton
539Card Reader - Invalid track Triton
54Operation time-out Triton
540Card Reader - Invalid message Triton
541Card Reader - Com error Triton
542Card Reader - Device busy Triton
543Card Reader - Sequence error Triton
544Card Reader - Invalid request Triton
545Card Reader - LRC error Triton
546Card Reader - No data Triton
547Card Reader - Start sentinel not found Triton
548Card Reader - End sentinel not found Triton
549Card Reader - Parity error Triton
55RAM corruption Triton
550Card Reader - Card not removed Triton
551Card Reader - Card removed to slow Triton
552"Card Reader - Device received invalid
request "Triton
553Card Reader - device offline Triton
554Card Reader - device reset Triton
555Card Reader - System timeout Triton
556System timeout Triton
557System device reset Triton
558System sync error Triton
559System error Triton
56Link error Triton
560Unknown device error Triton
561Software error Triton
562SPED error Triton
563Low Memory Triton
564"Unable to access external memory
device "Triton
565Cabinet door open Triton
566Vault door open Triton
567Security module not found Triton
568Security module com failed Triton
569"Security module attached dev com
failed "Triton
570Security module dev port setup Triton
571Invalid default transactionTriton
572"SPED key from pad cmd aborted by
user "Triton
573SPED keys from pad cmd verify failed Triton
574SNA comms error Triton
575"Timeout waiting to send command to
dispenser "Triton
576"Timeout waiting to receive response
from dispenser "Triton
577Card reader disabled Triton
578Card reader present timeout Triton
579SPED - Enable keypad command failedTriton
580SPED - Disable keypad command failedTriton
581"SPED - Enable key from pad module
failed "Triton
582SPED - Disable key from pad module Triton
583SPED - Enable PIN entry mode failed Triton
584SPED - Disable PIN entry mode failed Triton
585"SPED - Enable JETCO PIN entry mode
failed "Triton
586"SPED - Enable JETCO PIN entry mode
failed "Triton
587"NMD 50 required Cassette in TOP
hopper "Triton
588ERR PRESENTER OFFLINE Triton
589ERR PRESENTER MOTOR STALLED Triton
590ERR PRESENTER EXIT JAM Triton
591ERR PRESENTER PAPER NOT DETECTED Triton
592ERR SPED DEVICE REPORTED FAILED Triton
593ERR SPED IN USE Triton
594ERR SPED DEVICE REPORTED COMM ERROR Triton
595ERR SPED RETURNE INVALID AMOUNT OF DATA Triton
596ERR SPED INVALID SPED TYPE Triton
597ERR SPED INVALID SPED COMMS PROTOCOL Triton
598ERR_SPED_INVALID_DEVICE_CLASSTriton
599ERR SPED REPORTED UNRECOGNIZED COMMAND Triton
6BGD No Dial ToneTriton
600ERR SPED REPORTED BLOCK DOES NOT EXIST Triton
6001VERIFONE POWER ONVerifone
6001VERIFONE POWER ONTranax
6001CPU powered onWRG
6002CARD READ FAILUREVerifone
6002CARD READ FAILURETranax
6002"Card reader failure- Clean the card reader. If the card reader is not functioning contact WRG"WRG
6003NO DIAL TONEVerifone
6003NO DIAL TONETranax
6003"No dial tone- Check the phone line. If the phone line and able are working properly enable dial tone bypass in the Terminal Configuration menu. Test the CDU if the problem still remains contact WRG. "WRG
6004"MODEM DIALED NO CONNECTION"Verifone
6004"MODEM DIALED NO CONNECTION"Tranax
6004"Modem dialed no connection- if the phone line and cable are working properly contact WRG"WRG
6005"MODEM CONNECTED NO COMMUNICATION"Verifone
6005"MODEM CONNECTED NO COMMUNICATION"Tranax
6005Modem connected no communications- Check the phone lineWRG
6006INTERNAL PIN PAD FAILUREVerifone
6006INTERNAL PIN PAD FAILURETranax
6006Internal pin pad failure (automatic reset)WRG
6007Dial attempt failedTranax
6007Dial attempt failedWRG
6008Packet frame errorWRG
601ERR SPED REPORTED INVALID ENCRYPT MODE Triton
6012Luhn Check (Mod-10) card failure. (Incorrect card format)WRG
6013Line busyTranax
6013Line BusyWRG
6014No carrierTranax
6014No CarrierWRG
6015Working key receivedWRG
6016No EOT received in message from HostWRG
6017Message ErrorWRG
602ERR SPED REPORTED UNSUPPORTED CLEAR OPTION Triton
603ERR SPED REPORTED TAMPER PRESENT Triton
604ERR SPED REPORTED INVALID KEY INDEX Triton
605ERR SPED REPORTED PARENT KEY NOT LOADED Triton
606ERR SPED REPORTED WRONG DATA LENGTH Triton
607ERR SPED REPORTED PIN RETRY TOO SOON Triton
608ERR SPED SELFTEST CRC FAILED Triton
609ERR SPED SELFTEST CRYPTOGRAPHIC ERROR Triton
610ERR SPED SELFTEST BATTERY LOW STATUS Triton
6102External card reader failureTranax
6102"External card reader failure- Clean the card reader. If the reader is still not functioning contact WRG"WRG
611ERR SPED SELFTEST SERIAL NUMBER ERROR Triton
612ERR SPED TAMPER STATUS COLD Triton
613ERR SPED TAMPER STATUS FRONTTriton
614ERR_SPED_TAMPER_STATUS_BACKTriton
615ERR SPED TAMPER STATUS GRID Triton
616ERR SPED TAMPER STATUS VOLTAGE Triton
617ERR SPED SERIAL NUMBER CHANGE Triton
618SPED serial number change Triton
619NMD 100 shutter failed after reset Triton
620NMD 100 shutter OK after reset Triton
621SPED unrecoverable device tamperTriton
6417No Master Key Part 1WRG
65Cassette shuffled (TDM Click Counter 117)Triton
6517No Master Key Part 2WRG
6617No MAC Key Part 1WRG
6618No MAC Key Part 2WRG
7001Partial download requestedWRG
7002Partial download failedWRG
7003Partial download completedWRG
7101Full download requestedTranax
7101Full download requestedWRG
7102Full download failedWRG
7103Full download completedWRG
76Communications error with EJ Triton
8001Headphones plugged into the audio jackWRG
8002Headphones unplugged from audio jackWRG
8216091Cash jammed on Cash DispenserTranax
8216091Cash jammed on Cash DispenserHyosung
8217091Card in card readerTranax
8217091Card in card readerHyosung
8218091PBM EXISTHyosung
89Unexpected note in extension (TDM Click Counter 183)Triton
97221000Non-Indexed value for Indexed FieldHyosung
972210000Invalid FieldHyosung
9722100000Invalid Field (This Field's width is 0)Hyosung
90001Error during card swipeTranax
90001Card Swipe Error.Genmega
90001Card Reader errorHyosung
9000100Receipt paper empty.Hyosung
90002Invalid IC card communicationTranax
90002Invalid IC card communication errorHyosung
9000200Receipt paper setting error.Hyosung
90003DIP MCR latch failureTranax
90003DIP MCR latch failureHyosung
9000300Receipt Printer DIP switch error.Hyosung
90004DIP MCR unlatch failureTranax
90004DIP MCR unlatch failureHyosung
9000400Receipt Printer Lever OpenedHyosung
90005DIP MCR power on failureTranax
90005DIP MCR power on failureHyosung
9000500Receipt Printer cutter error.Hyosung
90006DIP MCR power off failureTranax
90006DIP MCR power off failureHyosung
9000600Receipt Printer connection failure.Hyosung
9001MAC check Value Error- MAC Check value in the message received from the Host is incorrect. The transaction is reversed. If this problem continues then a new set of MAC keys should be entered into the terminal and bound at the Host. WRG
9009File system corruptTranax
9009File system corrupt WRG
95"Multiple cassettes of the same type
installed "Triton
96Extension cable error (TDM Click Counter 186)Triton
97Extension exit trailing edge timeout (TDM Click Counter 121)Triton
9701010Failed to connect communication between SP of PIN and EP of oneTranax
9701010"Failed to connect communication between SP of
PIN and EP of one"Hyosung
9701012Failed to deliver to data of EPPs SPTranax
9701012Failed to deliver to data of EPP�s SPHyosung
9701016Received data time out of EPPTranax
9701016Received data time out of EPPHyosung
9701017Delivered data time out of EPPTranax
9701017Delivered data time out of EPPHyosung
9701031Failed to read Register of EPPTranax
9701031Failed to read Register of EPPHyosung
9701040Failed to produce Thread of EPPTranax
9701040Failed to produce Thread of EPPHyosung
9701060Failed to create bufferTranax
9701060Failed to create bufferHyosung
9701111BCC error of EPPTranax
9701111BCC error of EPPHyosung
9701150Pinpad (EPP) is down when it receives an 'Initializing� commandHyosung
9701151EPP is down when it receives an Get Status commandTranax
9701151EPP is down when it receives an 'Get Status' commandHyosung
9701152EPP is down when it receives an Clear Func Key commandTranax
9701152EPP is down when it receives an 'Clear Func Key' commandHyosung
9704034Failed to delete fileHyosung
9704040Failed to create ThreadHyosung
9704043Failed to terminate ThreadHyosung
9704050Failed to create ProcessHyosung
9704053Failed to terminate ProcessHyosung
9704060Failed to create MemoryHyosung
9704061Failed to read MemoryHyosung
9704062Failed to write MemoryHyosung
9704063Failed to close MemoryHyosung
9704068Invalid pointerHyosung
9704070Failed to create MutexHyosung
9704073Failed to release MutexHyosung
9704076Failed to wait time out MutexHyosung
9704080Failed to create EventHyosung
9704086Failed to wait time out EventHyosung
9704100Failed to connect polling or timeoutHyosung
9704101Failed to connect polling or line errorHyosung
9704102Timeout to send pollingHyosung
9704103Failed to close polling or timeoutHyosung
9704104Failed to close polling or line errorHyosung
9712000Failed to create fileTranax
9712000Failed to create fileHyosung
9712100Failed to read fileTranax
9712100Failed to read fileHyosung
9712200Failed to write fileTranax
9712200Failed to write fileHyosung
9712300Failed to close fileTranax
9712300Failed to close fileHyosung
9712400Failed to delete fileTranax
9712400Failed to delete fileHyosung
9712500Failed to copy fileTranax
9712500Failed to copy fileHyosung
9712600Failed to create directoryTranax
9712600Failed to create directoryHyosung
9719000Failed to execute an extra command in the status of Cash Unit ExchangeTranax
9719000Failed to execute an extra command in the status of Cash Unit ExchangeHyosung
9719100In case of not being the status of Cash Unit Exchange out of End ExchangeTranax
9719100"In case of not being the status of Cash Unit
Exchange out of End Exchange"Hyosung
9719200In case of carrying out Cash In Start command at two timesTranax
9719200In case of carrying out Cash In Start command at two timesHyosung
9719300In case of not being the status of Cash In out of End Cash InTranax
9719300In case of not being the status of Cash In out of End Cash InHyosung
9719400Invalid Cash Unit IDTranax
9719400Invalid Cash Unit IDHyosung
9719500Invalid Cash Unit numberTranax
9719500Invalid Cash Unit numberHyosung
9719600The abnormal of the number of Cash UnitTranax
9719600The abnormal of the number of Cash UnitHyosung
9719700No. of dispensed notes that software counts is not matched to it cash dispenser respondedTranax
9719700No. of dispensed notes that software counts is not matched to it cash dispenser respondedHyosung
971A000Invalid denominationTranax
971A000Invalid denominationHyosung
971A100Invalid currencyTranax
971A100Invalid currencyHyosung
971A200CASSETTE OFF POSITION. Not dispensableTranax
971A200CASSETTE OFF POSITION�. Not dispensableHyosung
971A300In case the number of bills dispensedexceeds the maximum dispensing billTranax
971A300In case the number of bills dispensed exceeds the maximum dispensing billHyosung
971A400In case the number of coins dispensedexceeds the maximum dispensing coinTranax
971A400In case the number of coins dispensed exceeds the maximum dispensing coinHyosung
971A500Invalid mix numberTranax
971A500Invalid mix numberHyosung
971A600In case automatic Retry of SP fails 3 timesTranax
971A600In case automatic Retry of SP fails 3 timesHyosung
971A700There is no setting information about automatic Retry standardTranax
971A700"There is no setting information about automatic
Retry standard"Hyosung
971B000In case of being executed Reject or Retract command without being the bills in stacker.Tranax
971B000"In case of being executed Reject or
Retract command without being the bills in stacker."Hyosung
971C000Not supported commandTranax
971C000Not supported commandHyosung
971D100Partial dispenseTranax
971D100Partial dispenseHyosung
971D200Partial dispense from cassette #2Tranax
971D200Partial dispense from cassette #2Hyosung
971D300Partial dispense from cassette #3Tranax
971D300Partial dispense from cassette #3Hyosung
971DX00In case partial bills dispensed by dispensing demand when Partial Dispense option is on. E?R-. X means cassette number.Tranax
971DX00"In case partial bills dispensed by dispensing demand when Partial Dispense option is on.
? �X� means cassette number."Hyosung
9720000Receipt printer communication error during SP openingTranax
9720000Receipt printer communication error during SP openingHyosung
9721111Off line statusTranax
9721111Off line statusHyosung
9721112On busyTranax
9721112On busyHyosung
9721121Mechanics ErrorTranax
9721121Mechanics ErrorHyosung
9721122Recoverable ErrorTranax
9721122Recoverable ErrorHyosung
9721123Unrecoverable ErrorTranax
9721123Unrecoverable ErrorHyosung
9721124Paper jammedTranax
9721124Paper jammedHyosung
9722010Receipt Printer communication failure during COM port openTranax
9722010Receipt Printer communication failure during COM port openHyosung
9722020File Open Error1.Reboot ATMTranax
9722020File Open ErrorHyosung
9722060Memory Allocate Error(PrintForm Allocate IndexBuffer Fail)Tranax
9722060"Memory Allocate Error
(PrintForm Allocate IndexBuffer Fail)"Hyosung
9722068Invalid Media Name1.Reboot ATMTranax
9722068Invalid Media NameHyosung
972210Field is not FoundHyosung
9722100Field Error (This Field must have initial value)Tranax
9722100Field Error (This Field must have initial value)Hyosung
9722105Invalid Form1.Reboot ATMTranax
9722106PrintForm() offset is InvalidTranax
97221A2Invalid Unit1.Reboot ATMTranax
97221A2Invalid UnitHyosung
97221C1Form is not Found1.Reboot ATMTranax
97221C1Form is not FoundHyosung
97221C4Form Name is NULL1.Reboot ATMTranax
97221C4Form Name is NULLHyosung
97221C5Invalid FormHyosung
97221C6PrintForm() offset is InvalidHyosung
97221C7Invalid Form (Too many Fields)Hyosung
97221D1Media is not Found1.Reboot ATMTranax
97221D1Media is not FoundHyosung
97221D3Media Overflow when form size is larger than media sizeTranax
97221D3Media Overflow when form size is larger than media sizeHyosung
97221D4Media Name is NULL1.Reboot ATMTranax
97221D4Media Name is NULLHyosung
97221D5Invalid Media (Attribute for Media definition is not proper)Tranax
97221D5Invalid Media (Attribute for Media definition is not proper)Hyosung
97221D6Invalid Media (Area size is larger than media size)Tranax
97221D6Invalid Media (Area size is larger than media size)Hyosung
97221D7Invalid Media (Size of Media Name is exceeded to 2048 bytes totally)Tranax
97221D7Invalid Media (Size of Media Name is exceeded to 2048 bytes totally)Hyosung
972210Field is not FoundHyosung
9722100Field Error (This Field must have initial value)Hyosung
97221000Non-Indexed value for Indexed FieldHyosung
972210000Invalid FieldHyosung
9722100000Invalid Field (This Field's width is 0)Hyosung
9722DN0Receipt Printer communication failure during sending command to Receipt PrinterTranax
9722DN0Receipt Printer communication failure during sending command to Receipt PrinterHyosung
9723010Failed to open deviceTranax
9723010Failed to open deviceHyosung
9723011Communication errorTranax
9723011Communication errorHyosung
9723016Time out to receive dataTranax
9723016Timeout to receive dataHyosung
9723019Polling downTranax
9723019Polling downHyosung
9730100IC CARD DENIALTranax
9730100IC card denialHyosung
9730200IC CARD ONLINE DATA ERRORTranax
9730200IC card online data errorHyosung
9730300IC CARD ERRORTranax
9730300IC card errorHyosung
9740000Cash Dispenser communication failure during COM port openTranax
9740000Cash Dispenser communication failure during COM port openHyosung
9740010Open Port FailTranax
9740020Failed to create fileTranax
9740020Failed to create fileHyosung
9740025Failed to copy fileTranax
9740025Failed to copy fileHyosung
9740030Invalid registry key concerning dateTranax
9740031Invalid date to print check to be dispensedTranax
97400FFSome bills are remaining at CDU's transportTranax
9740101In case incorrect cassette type is set.Tranax
9740101In case incorrect cassette type is set.Hyosung
9740102In case nonexistent Note Index is set.Tranax
9740102In case nonexistent Note Index is set.Hyosung
9741100When sensing CS2 Dark (Error code 400FFOO is subdivided by location of sensor.)Tranax
9741100"When sensing CS2 Dark (Error code 400FF00 is subdivided by location of sensor.)"Hyosung
9741400When sensing CS4A Dark (Error code 400FFOO is subdivided by location of sensor.)Tranax
9741400"When sensing CS4A Dark (Error code
400FF00 is subdivided by location of sensor.)"Hyosung
9741800When sensing CS4B Dark (Error code 400FFOO is subdivided by location of sensor.)Tranax
9741800"When sensing CS4B Dark (Error code
400FF00 is subdivided by location of sensor.)"Hyosung
9742100When sensing CS21AB Dark (Error code 400FFOO is subdivided by location of sensor.)Tranax
9742100"When sensing CS21AB Dark (Error code
400FF00 is subdivided by location of sensor.)"Hyosung
9742800When sensing CS13 Dark (Error code 400FFOO is subdivided by location of sensor.)Tranax
9742800"When sensing CS13 Dark (Error code
400FF00 is subdivided by location of sensor.)"Hyosung
9743B00When sensing CS15AB Dark (Error code 400FFOO is subdivided by location of sensor.)Tranax
9743B00"When sensing CS15AB Dark (Error code
400FF00 is subdivided by location of sensor.)"Hyosung
9744700Cash picking-up fail while cash in cassette #1 is enoughTranax
9744700Cash picking-up fail while cash in cassette #1 is enoughHyosung
9745500System power off while dispensingTranax
9745500System power off while dispensingHyosung
9745B00Cash picking-up fail while cash in cassette #2 is enoughTranax
9745B00Cash picking-up fail while cash in cassette #2 is enoughHyosung
9746B00When sensing CS31AB Dark (Error code 400FFOO is subdivided by location of sensor.)Tranax
9746B00"When sensing CS31AB Dark (Error code
400FF00 is subdivided by location of sensor.)"Hyosung
9747B00When sensing CS41A B Dark (Error code 400FFOO is subdivided by location of sensor.)Tranax
9747B00"When sensing CS41A B Dark (Error code
400FF00 is subdivided by location of sensor.)"Hyosung
9747C00Cash picking-up fail while cash in cassette #4 is enoughTranax
9747C00Cash picking-up fail while cash in cassette #4 is enoughHyosung
9749F00Cash picking-up fail while cash in cassette #3 is enoughTranax
9749F00Cash picking-up fail while cash in cassette #3 is enoughHyosung
974FF00When sensing bills in the Stacker (Error code 400FFOO is subdivided by location of sensor.)Tranax
974FF00"When sensing bills in the Stacker (Error code
400FF00 is subdivided by location of sensor.)"Hyosung
9770011Receive data failHyosung
9770012Send data failHyosung
9770013Serial port close failHyosung
9770016Receive data timeoutHyosung
9770017Send data timeoutHyosung
9770032Registry write failHyosung
9770034Registry delete failHyosung
9770040Thread create failHyosung
9770043Thread close failHyosung
9770050ComMonitor4WBA.EXE create failHyosung
9770060Shared Memory creation failHyosung
977010Serial port open failHyosung
9770111Transmitting incorrect commandHyosung
9770121No defined currencyHyosung
9770122"Not setting deposit direction and Inquire Accept() method"Hyosung
9770123"Not setting deposit denomination and Inquire Accept() method"Hyosung
9770124Set incorrect denomination when executing Enable()/Disable()Hyosung
9770125Set incorrect direction when executing Direction() methodHyosung
9770150Call Direction()/Enable()/Disable() method under no initializationHyosung
979113XDEVVFD Time over Error Code_ Tranax
97911XXDEVJPR Time over Error Code_ Tranax
97911XXDEV_JPR Timeover Error CodeHyosung
97912XXDEVSPR Time Over Error_ Tranax
97912XXDEV_SPR Time Over ErrorHyosung
97913XXDEV_MCU Time over Error CodeTranax
97913XXDEV_MCU Time overHyosung
97914XXDEV_ Cash Dispenser Time over Error CodeTranax
97914XXDEV_Cash Dispenser Time over Error CodeHyosung
97915XXDEVBRM Time over Error Code_ Tranax
97915XXDEV_BRM Time over Error CodeHyosung
97916XXDEVPBM Time over Error Code_ Tranax
97916XXDEV_PBM Time over Error CodeHyosung
97918XXDEVPIN Time over Error Code_ Tranax
97918XXDEV_PIN Time over Error CodeHyosung
9791AXXDEVFNG Time over Error Code_ Tranax
9791AXXDEV_FNG Time over Error CodeHyosung
9791BXXDEV_VFD Time over Error CodeHyosung
97921XXDEV_JPR FATALERROR (WARNING)Tranax
97921XXDEV_JPR FATALERROR (WARNING)Hyosung
9792201Receipt Printer Communication FailureTranax
97922XXDEV_SPR FATALERROR (WARNING)Hyosung
9792309Card Reader ErrorTranax
97923XXDEV_MCU FATALERROR (WARNING)Tranax
97923XXDEV_MCU Fatal errorHyosung
97924XXDEV_Cash Dispenser FATAL ERROR (WARNING)Tranax
97924XXDEV_Cash Dispenser FATAL ERROR (WARNING)Hyosung
97925XXDEV_BRM FATALERROR (WARNING)Tranax
97925XXDEV_BRM FATALERROR (WARNING)Hyosung
97926XXDEV_PBM FATALERROR (WARNING)Tranax
97926XXDEV_PBM FATALERROR (WARNING)Hyosung
97928XXDEV_PIN FATALERROR (WARNING)Tranax
97928XXDEV_PIN FATALERROR (WARNING)Hyosung
9792AXXDEV_FNG FATALERROR (WARNING)Tranax
9792AXXDEV_FNG FATALERROR (WARNING)Hyosung
9792BXXDEV_VFD FATALERROR (WARNING)Hyosung
9799301MCU RETRACT OVERTranax
9799301MCU retract overHyosung
9799499DISPENSER COUNT ERRORTranax
9799499DISPENSER COUNT ERRORHyosung
9799601PBM RETRACT OVERHyosung
9799901DOOR CHECK1.Reboot ATMTranax
9799901DOOR CHECKHyosung
9799902LIGHT ERROR1.Reboot ATMTranax
9799902LIGHT ERRORHyosung
9799903SPL ERROR1.Reboot ATMTranax
9799903SPL ERRORHyosung
9799904PIN ERROR1.Reboot ATMTranax
9799904PIN ERRORHyosung
9799905SENSOR CHECK1.Reboot ATMTranax
9799905SENSOR CHECKHyosung
9799907UPS ERROR1.Reboot ATMTranax
9799907UPS ERRORHyosung
9799908SCREEN ERROR1.Reboot ATMTranax
9799908SCREEN ERRORHyosung
98Extension exit timeout (TDM Click Counter 119)Triton
99Extension skew detected (TDM Click Counter 120)Triton
9900000A given command code is unidentifiedHyosung
9900001Parameter is not correctHyosung
9900002Command execution is impossible under Supervisor program code areaHyosung
9900003Hardware is not presentHyosung
9900004Command Data ErrorHyosung
9900006MCR does not have keys that decipher the data.Hyosung
9900010card jamHyosung
9900011shutter failureHyosung
9900012"sensor failure of PD1PD2PD3PDI/Card remains inside."Hyosung
9900013Irregular card length(LONG)Hyosung
9900014Irregular card length(SHORT)Hyosung
9900015F-ROM errorHyosung
9900016The Card was moved forciblyHyosung
9900017jam error at retrieveHyosung
9900018SW1 or SW2 errorHyosung
9900020Read Error (Parity Error)Hyosung
9900021Read Error (Other)Hyosung
9900023Read Error (Only SS-ES-LRC)Hyosung
9900024Read Error (no encode and/or no magnetic stripe)Hyosung
9900026Read Error (No SS)Hyosung
9900027Read Error (No ES)Hyosung
9900028Read Error (LRC Error)Hyosung
9900030Power DownHyosung
9900040Card was pulled out during captureHyosung
9900045MCR ejected the card forciblyHyosung
9900046The ejected card has not been withdrawn until the specified time.Hyosung
9900050Retract counter overflowHyosung
9900051Motor errorHyosung
9900053Digital decode read errorHyosung
9900070F-Rom write ErrorHyosung
9900071CRC error of user program code areaHyosung
99000A0The card does not exist at the hopperHyosung
99000A1There is a card at the lead line.Hyosung
99000A2Transmission error between hopper and MCR(time over)Hyosung
99000A4The guide door at hopper is openHyosung
99000A5The card jam at the hopper.Hyosung
99000A6The hopping kicker could not return to the home positionHyosung
99000B0Not received Initialize CommandHyosung
99000SAUnder MSM's Supervisor program code areaHyosung
99000xxxx : EP Error Code? Refer to specifications for EP Error CodeHyosung
9900101Cannot create object errorHyosung
9900102Device Not Ready ErrorHyosung
9900103Cannot open port ErrorHyosung
9900104Failed to begin thread errorHyosung
9900105Device Already ConnectedHyosung
9900400Retain bin FullHyosung
9900444Media JamHyosung
9900445Hopper EmptyHyosung
9901000Device Not ConnectedHyosung
9902000Cancel Command Session errorHyosung
9903000Failed to send command errorHyosung
9904000Failed to receive reply errorHyosung
9905000Command CanceledHyosung
9906000Reply TimeoutHyosung
991@@91ON TRANSACTION POWER OFFTranax
991@@91ON TRANSACTION POWER OFFHyosung
9910000SP Internal ErrorHyosung
9974180CS4B Sensor is DarkHyosung
99F0000Unknown Error CodeHyosung
A00Printer MalfunctionTriton
A0008Receipt paper cutter errorTranax
A0011Lever open detect before commandTranax
A0012Printer thermal head over heated before commandTranax
A0013Paper jam before commandTranax
A0014Paper setting error before commandTranax
A0015Paper check error before commandTranax
A0018Cutter S/W check error before commandTranax
A0081Lever open detect in doing commandTranax
A0082Printer thermal head over heated in doing commandTranax
A0083Paper jam in doing commandTranax
A0084Paper setting error in doing commandTranax
A0085Paper check error in doing commandTranax
A0088Cutter S/W check error in doing commandTranax
A01Check Printer Feed LeverTriton
A0101Open lever detected before executing commandTranax
A010100Open lever detected before executing commandTranax
A010100Open lever detected before executing commandHyosung
A0102Printer thermal head overheated while executing commandTranax
A010200Printer thermal head overheated while executing commandTranax
A010200Printer thermal head overheated while executing commandHyosung
A0103Paper jam detected before executing commandTranax
A010300Paper jam detected before executing commandTranax
A010300Paper jam detected before executing commandHyosung
A0104Paper setting error detected before executing commandTranax
A010400Paper setting error detected before executing commandTranax
A010400Paper setting error detected before executing commandHyosung
A0105Paper check error detected before executing commandTranax
A010500Paper check error detected before executing commandTranax
A010500Paper check error detected before executing commandHyosung
A0106Offline error Offline mode is engaged(Mis-handling)Tranax
A0107Remaining paper error Insufficient paperTranax
A0108Paper cutter software check error detected before executing commandTranax
A010800Paper cutter software check error detected before executing commandTranax
A010800Paper cutter software check error detected before executing commandHyosung
A0109Failed to detect B/M Black marker sensor detection fails(Abnormal Mecha) Only when B/M is availableTranax
A010AImage Data Size ErrorTranax
A08Receipt Printer ErrorTriton
A0801Open lever detected while executing commandTranax
A080100Open lever detected while executing commandTranax
A080100Open lever detected while executing commandHyosung
A0802Receipt printer head overheated while printingTranax
A080200Receipt printer head overheated while printingTranax
A080200Receipt printer head overheated while printingHyosung
A0803Receipt paper jamTranax
A080300Paper jam detected while executing commandTranax
A080300Paper jam detected while executing commandHyosung
A0804Paper setting error detected before executing commandTranax
A080400Paper setting error detected before executing commandTranax
A080400Paper setting error detected before executing commandHyosung
A0805Paper check error in doing commandTranax
A080500Paper check error in doing commandTranax
A080500Paper check error in doing commandHyosung
A0806Offline error Offline mode is engaged(Mis-handling)Tranax
A0807Remaining paper error Insufficient paperTranax
A0808Receipt Paper JamTranax
A080800Paper cutter software check error detected while executing commandTranax
A080800Paper cutter software check error detected while executing commandHyosung
A0809Failed to detect B/M Back marker sensor detection fails(Abnormal Mecha) Only when B/M is availableTranax
A080AImage Data Size ErrorTranax
ADN01No response detected for 30 seconds after sending commandTranax
ADN0100No response detected for 30 seconds after sending commandTranax
ADN0100No response detected for 30 seconds after sending commandHyosung
ADN04Printer connection errorTranax
ADN0APrinter connection errorTranax
ADN0FPrinter connection errorTranax
ADN0F00No response detected for 30 seconds after sending commandHyosung
ADN10No Response for 30 seconds after send commandTranax
ADN11No response detected after 3 retriesTranax
ADN1100No response detected after 3 retriesTranax
ADN1100No response detected after 3 retriesHyosung
ADN12No response detected between ENQ-ACK after 5 retries of ENQTranax
ADN1200No response detected between ENQ-ACK after 5 retries of ENQTranax
ADN1200"No response detected between ENQ-ACK after
5 retries of ENQ"Hyosung
ADN13No response detected after 5 retries because of timeout between STX-BCC intervalTranax
ADN1300No response detected after 5 retries because of timeout between STX-BCC intervalTranax
ADN1300No response detected after 5 retries because of timeout between STX-BCC intervalHyosung
ADNOF00No response detected for 30 seconds after sending commandTranax
ADNxxPrinter connection error.Genmega
ADNXX00Cash cassette taken out during dispenseHyosung
Application Flash ErrorTidel
Axxx1Receipt printer feed lever open - during operationTranax
Axxx1Receipt Printer feed lever open � during operation.Genmega
AXXX100CDU sensor blocked.Hyosung
Axxx2Thermal printer is overheated - during operationTranax
Axxx2"Thermal printer is overheated
� during operation."Genmega
AXXX200CDU main motor failure.Hyosung
Axxx3Receipt Paper JamTranax
Axxx3Receipt paper jam.Genmega
AXXX300CDU outlet solenoid echo error.Hyosung
Axxx4Receipt paper is emptyTranax
Axxx4Receipt paper is empty.Genmega
AXXX400CDU encoder error.Hyosung
Axxx5Receipt paper is jamming during loadingTranax
Axxx5Receipt paper is jamming during loading.Genmega
AXXX500CDU double detect module failure 1Hyosung
AXXX6Appears while doing the manual self-testTranax
AXXX600CDU double detect module failure 2Hyosung
AXXX7Receipt printer feed lever is in the open positionTranax
AXXX700Note detected (outlet sensor)Hyosung
Axxx8Receipt paper cutter errorTranax
Axxx8Receipt Printer cutter error.Genmega
AXXX800CDU double detect module failure 3Hyosung
B0001Expanded Flash memory errorTranax
B000100Dispensing errorHyosung
B4300(00)Stacker fullHyosung
B4400(00)Stacker openHyosung
B4500(00)Jam in acceptorHyosung
B4600(00)Jam in stackerHyosung
B4700(00)Pause conveyingHyosung
B4900(00)Device execution failHyosung
B49A2(00)Stack motor failHyosung
B49A5(00)Transport motor speed failHyosung
B49A6(00)Transport motor failHyosung
B49AB(00)Cash box not readyHyosung
B49AF(00)Validator head removeHyosung
B49B0(00)Boot ROM failHyosung
B49B1(00)External ROM failHyosung
B49B2(00)ROM failHyosung
B49B3(00)External ROM writing failHyosung
Bad FloppyTidel
Bad roller profileTidel
BDN00(00)Communication failureHyosung
Bill count equals zeroTidel
Bin Block check char errorTidel
Bin cmd receive timeoutTidel
Bin cmd transmit timeoutTidel
Bin eot not receivedTidel
Bin failed com writeTidel
Bin no ack receivedTidel
Blocked ExitTidel
C0000Cash Dispenser(CDU) received the undefined command from AP softwareTranax
C0001 ~ C002FThe feed lever of the receipt printer is open. It was detected that the feed lever was open while the receipt printer was operating.Tranax
C0011CDU sensor is tripped Tranax
C0011Exit sensor is not clearedGenmega
C0012Reject gate timing sensor not cleared.Genmega
C0013Both reject gate and exit sensor not clearedGenmega
C0014CS4A sensor detects note in delivery path before/after CDU dispensesTranax
C0015CS2 or CS4A sensor detects note in delivery path before/after CDU dispensesTranax
C0017Undefined ErrorGenmega
C0018CS4B sensor detects note in delivery path before/after CDU dispensesTranax
C0019CS2 or CS4B sensor detects note in delivery path before/after CDU dispensesTranax
C001CCS4A or CS4B sensor detects note in delivery path before/after CDU dispensesTranax
C001D"CS2 CS4A or CS4B sensor detects note in delivery path before/after CDU dispenses"Tranax
C001xCDU sensor is trippedTranax
C001YCDU Sensor is covered (1)Y is hexadecimal of sensor which was covered (Y could be 0x30 ~ 0x3F)2^3 = NS3B2^2 = NS3A2^1 = NS72^0 = Reservedex) 'C0015' : NS3A is covered This Error usually happens during initializing or after dispensing noteTranax
C001Y00Note jamHyosung
C0021CS1A sensor detects note in delivery path before/after CDU dispensesTranax
C0021Double detect sensor is not cleared.Genmega
C0022CS1B sensor detects note in delivery path before/after CDU dispensesTranax
C00221st cassette inlet sensor not cleared.Genmega
C0023CS1A or CS1B sensor detects note in delivery path before/after CDU dispensesTranax
C0023Cassette exit sensor (L+R) not cleared.Genmega
C0028CS13 sensor detects note in delivery path before/after CDU dispensesTranax
C0028Count sensors not clearedGenmega
C0029CS1A or CS13 sensor detects note in delivery path before/after CDU dispensesTranax
C002ACS1B or CS13 sensor detects note in delivery path before/after CDU dispensesTranax
C002B"CS1A CS1B or CS13 sensor detects note in delivery path before/after CDU dispenses"Tranax
C002xCDU sensor is trippedTranax
C002Y"CDU Sensor is covered (2)Y is hexadecimal of sensor which was covered (Y could be 0x30 ~ 0x3F)2^3 = NS4B2^2 = Reserved2^1 = NS2B2^0 = NS2Aex) 'C0023' : NS2A NS2B is coveredThis Error usually happens during initializing or after dispensing note"Tranax
C002Y00Over 10 notes has been rejected per 1 transaction.Hyosung
C0030CDU motor failureTranax
C0030Main Motor encoder is not synchronizedGenmega
C003000Over 5 notes has been rejected continuously.Hyosung
C0031CDU Gate solenoid errorTranax
C0031Forward motor encoder not synchronized.Genmega
C003100Too many notes dispensed continuously.Hyosung
C0032Outlet solenoid errorTranax
C00321st cassette inlet sensor not clearedGenmega
C003200CDU hardware failureHyosung
C0033CDU Encoder errorTranax
C0033CDU data setting errorGenmega
C0033001st Cassette MisfeedHyosung
C0034Double Note detect module failureTranax
C003400Wrong count.Hyosung
C0035Double Note detect module failure (2)Tranax
C003500Note jam.Hyosung
C0036Detected notes in path before initializingTranax
C0036Exit sensor blocked while initializingGenmega
C003600Many notes too close.Hyosung
C0037Double detect failure (During dispense)Tranax
C0037"Invalid response (or no response) from double detect
sensor"Genmega
C003700Wrong countHyosung
C0038SRAM check errorTranax
C003800Cash cassette is not properly setHyosung
C0039Gate sensor open during initializingTranax
C0039Solenoid not respondingGenmega
C003900Wrong countHyosung
C003A4 or more bills requestedTranax
C003AToo many notes requested during a test dispenseGenmega
C003A00Wrong count(over dispensed)Hyosung
C003BNotes detected during installationTranax
C003B00Power failed during dispensingHyosung
C0040Cassette removed during dispenseTranax
C004000Too many notes requestedHyosung
C0041Tried to dispense notes more than 5 timesTranax
C0041"Failed (5 times) to dispense a note after a successful
dispense"Genmega
C004100"Note detected(CS1A CS1B)"Hyosung
C0042Note jamTranax
C0042Mismatch between requested notes and dispensed notesGenmega
C004200CDU double detect module failure 4Hyosung
C0043More than 10 notes rejected during one transactionTranax
C0043"10 Notes rejected in a row
(single transaction)"Genmega
C004300Long note detected(outlet sensor)Hyosung
C0044More than 5 notes rejected consecutivelyTranax
C00445 notes consecutively rejectedGenmega
C0044002nd Cassette MisfeedHyosung
C0045More bills dispensed than requested.Tranax
C0045Note count sensor reporting mismatchGenmega
C0045003rd Cassette MisfeedHyosung
C0046CDU Hardware FailureTranax
C0046CDU Hardware failureGenmega
C004600CDU connection failure.Hyosung
C0047Feed errorTranax
C00471st cassette failed to dispense a noteGenmega
C004700Modem reset failureHyosung
C0048Incorrect bill countTranax
C004800Reversal failureHyosung
C0049Request to dispense 0 notesTranax
C0049Dispense request of �0� notesGenmega
C004900Transaction Error responded by HostHyosung
C004AJammed notesTranax
C004A"First cassette exit sensor (#6
#7) not clear"Genmega
C004A00Communication ErrorHyosung
C004BLong note detected 3 times consecutivelyTranax
C004B00RMS port failureHyosung
C004CMiscount of notes between sensorsTranax
C004C00RMS response timeoutHyosung
C004DCash cassette not properly setTranax
C004D1st cassette not insertedGenmega
C004D00RMS modem failureHyosung
C004EMiscount of notes between sensorsTranax
C004E2nd cassette not insertedGenmega
C004E00RMS no dial toneHyosung
C004FMiscount of notes between sensorsTranax
C004F00The Number of dispensed notes does not matchTranax
C004F00The Number of dispensed notes does not matchHyosung
C0050Power failure during dispenseTranax
C0050AP does not receive response after dispense requestGenmega
C005000Number of Bill is not inputtedHyosung
C0051Over 150 notes requestedTranax
C0051"Exceeded maximum number of notes dispensed (150) in a
single trans."Genmega
C005100Surcharge Owner is not inputted in Surcharge EnableHyosung
C0052Detected notes in path after dispenseTranax
C00521st cassette inlet sensor not clearedGenmega
C005200Surcharge Amount is not inputted in Surcharge EnableHyosung
C0053CDU double detect module failure.Tranax
C0053Abnormal amount of double- detect failures during dispenseGenmega
C005300Refresh timer is not inputted in Advertisement EnableHyosung
C0054CDU program errorTranax
C0054Cash dispenser program errorGenmega
C005400Advertisement text is not inputted in Advertisement EnableHyosung
C0055Detected long notes at outlet sensorTranax
C0055Long note detected at exit sensor during dispenseGenmega
C005500Error in Dispense Limit settingHyosung
C0056Exit gate sensor failureTranax
C0056Short note detected at exit sensor during dispenseGenmega
C005600Error in inputting Note CurrencyHyosung
C0057Incorrect cassette info.Tranax
C005700Error in Fast Cash settingHyosung
C0058Reject bin is not in the correct positionTranax
C005800Reject bin is not in the correct positionHyosung
C0059Cassette #2 removed prior to dispenseTranax
C005900Master Key Index invalid(0 <= MKEY Index <= 15)Hyosung
C005ACassette #1 removed prior to dispenseTranax
C005ACash cassette 1 removed prior to dispenseGenmega
C005A00Master Key EmptyHyosung
C005BCassette #2 misfeedTranax
C005B2nd cassette fails to pick up notesGenmega
C005B00Host Phone Number is not inputtedHyosung
C005CReject bin note detect error (CS14)Tranax
C005C00Reject bin note detect error (CS14)Hyosung
C005DConstant double detectTranax
C005D00Error Retry Timer is not inputtedHyosung
C005EDispense size command errorTranax
C005E00RMS Password is not inputted in RMS EnableHyosung
C005FDispense ErrorTranax
C005F00RMS Phone Number is not inputted in RMS EnableHyosung
C0060"CS31A CS31B detected before dispensing"Tranax
C00603rd cassette inlet sensor not clearedGenmega
C006000"CS31A CS31B detected before dispensing"Hyosung
C0061"CS31A CS31B detected after dispenser motor on and before dispensing"Tranax
C006100"CS31A CS31B detected after dispenser motor on and before dispensing"Hyosung
C00623rd cassette inlet sensor not clearedGenmega
C0063"CS31A CS31B detected after dispensing"Tranax
C006300"CS31A CS31B detected after dispensing"Hyosung
C006ADispensing timeout error from CS15 to CS4Tranax
C006ANote jam at 2nd cassette exitGenmega
C006A00Dispensing timeout error from CS15 to CS4Hyosung
C006B"CS31A CS31B detected during initialization"Tranax
C006B00"CS31A CS31B detected during initialization"Hyosung
C006xSensor failureTranax
C006YCDU Sensor Half-Light Error 1Y is hexadecimal of Error Sensor (Y could be 0x30 ~ 0x3F)2^3 = NS3B2^2 = NS3A2^1 = NS72^0 = Reservedex) 'C0065' : NS3A ErrorTranax
C006Y00Terminal Number is not inputtedHyosung
C0070"CS41A CS41B detected before dispensing"Tranax
C00704th cassette inlet sensor not clearedGenmega
C007000"CS41A CS41B detected before dispensing"Hyosung
C0071Exceeded 200 note limitTranax
C007100Exceeded 200 note limitHyosung
C0072"CS41A CS41B detected after dispenser motor on"Tranax
C00724th cassette inlet sensor not clearedGenmega
C007200"CS41A CS41B detected after dispenser motor on"Hyosung
C0073"CS41A CS41B detected after dispensing"Tranax
C007300"CS41A CS41B detected after dispensing"Hyosung
C007ADispensing timeout error from CS15 to CS4Tranax
C007ANote jam at 4th cassette exitGenmega
C007A00Dispensing timeout error from CS15 to CS4Hyosung
C007B"CS31A CS31B detected error during initialization"Tranax
C007B00"CS31A CS31B detected error during initialization"Hyosung
C007C4th cassette misfeed errorTranax
C007C4th cassette fails to pick up notesGenmega
C007C004th cassette misfeed errorHyosung
C007D4th cassette taken out before dispensingTranax
C007D4th cassette not insertedGenmega
C007D004th cassette taken out before dispensingHyosung
C007xSensor failureTranax
C007Y"CDU Sensor Half-Light Error 2Y is hexadecimal of Error Sensor (Y could be 0x30 ~ 0x3F)2^3 = NS42^2 = Reserved2^1 = NS2B2^0 = NS2Aex) 'C0073' : NS2A NS2B Error"Tranax
C007Y00Routing ID is not inputtedHyosung
C0080"CS15A CS15B detected before dispensing"Tranax
C00802nd cassette inlet sensor not clearedGenmega
C008000"CS15A CS15B detected before dispensing"Hyosung
C0081"CS15A CS15B detected after motor on"Tranax
C0081Double detect sensor not cleared while dispensingGenmega
C008100Master Key Serial Number is not inputtedHyosung
C0082Shutter failureTranax
C0082Note leaving cassette exit sensor did not reach DDGenmega
C008200"Non-Cash Type text is not in/out(only MB-2100 2200)"Hyosung
C0083Stacker sensor failureTranax
C0083Reject gate timing sensor #2 not cleared during dispense.Genmega
C008300Parameter is not properly setHyosung
C0084Shutter close errorTranax
C0084Reject gate timing sensor #3 not cleared during dispense.Genmega
C008400NVRAM FailureHyosung
C0085Note leaving DD sensor did not reach gate sensorGenmega
C0086Note leaving gate sensor did not reach count sensorGenmega
C008FCS13 sensor detects the notes with holeTranax
C0090Sensor check errorGenmega
C0091Sensor check errorGenmega
C0092Sensor check errorGenmega
C0093Sensor check errorGenmega
C0094Sensor check errorGenmega
C0095Sensor check errorGenmega
C0096Sensor check errorGenmega
C0097Sensor check errorGenmega
C009ADispensing timeout error from CS31 to CS4Tranax
C009ANote jam at 3rd cassette exitGenmega
C009A00Dispensing timeout error from CS31 to CS4Hyosung
C009DNo cassette present before dispensing from 3rd cassetteTranax
C009D3rd cassette not insertedGenmega
C009D00No cassette present before dispensing from 3rd cassetteHyosung
C009F3rd cassette misfeed errorTranax
C009F3rd cassette fails to pick up notesGenmega
C009F003rd cassette misfeed errorHyosung
C00ABNote detected before initializing.Tranax
C00AB00Note has been detected on the path before the Cash Dispenser Unit initializing.Hyosung
C00C6Sensor blocked during initializing.Tranax
C00C700CS12 is Dark while initializing or dispensing (NH2100T)Hyosung
C00C8Bill jam during dispenseTranax
C00C800CS14 is Dark while initializing or dispensing (NH2100T)Hyosung
C00C9Bill jam during dispenseTranax
C00C900CS14 is Dark while initializing or dispensing (NH2100T)Hyosung
C00CCBill jam during dispenseTranax
C00D0Bill jam during dispenseTranax
C00D000CS13 ~ CS12 Sensor Timeout[Jam] (NH2100T)Hyosung
C00D1Bill jam during dispenseTranax
C00D100CS12 ~ CS14 Sensor Timeout[Jam] (NH2100T)Hyosung
C00E0NS2 Sensor DarkTranax
C00E000"NS2A NS2B dark"Hyosung
C00E1NS4 Sensor DarkTranax
C00E100NS4 darkHyosung
C00E2Flash erase failedTranax
C00FFSensor blocked N/ATranax
C1010OUT OF CASHTranax
C101000OUT OF CASHHyosung
C12Reject Gate Sensor BlockedTriton
C22CDU Inlet Sensors BlockedTriton
C37Double Detection Sensors BlockedTriton
C54CDU Exit Sensor BlockedTriton
C58Note Count Mismatch ErrorTriton
C81Double Detection Sensors BlockedTriton
C86No Note at Exit Sensor DetectedTriton
CANCECancelled transactionTranax
CANCESurcharge CancelGenmega
Card Reader FailureTidel
CasCloseNegative Balance Cassette Close NeededTriton
CasCloseNegative Balance Cassette Close NeededTranax
CasCloseNegative Balance Cassette Close NeededTidel
CasCloseNegative Balance Cassette Close NeededVerifone
CasCloseNegative Balance Cassette Close NeededHyosung
Cassette data corruptedTidel
Cassette exit sensor failureTidel
Cassette faultyTidel
Cassette lock faultyTidel
Cassette LowTidel
Cassette may have been changedTidel
Cassette needs calibrationTidel
Cassette not installedTidel
Cassette-X EmptyTidel
Cassette-X LowTidel
Cassette-X Zero document countTidel
CD0Cardholder forgot to remove Chip CardTriton
CDN01No response detected after sending commandTranax
CDN0100No response detected after sending commandHyosung
CDN04CDU connection failureTranax
CDN0FNo response detected after sending commandTranax
CDN0F00No response detected after sending commandHyosung
CDN11No response detected after 3 retries of sending commandTranax
CDN1100No response detected after 3 retries of sending commandHyosung
CDN12No response detected between ENQ-ACK after 5 retries of ENQTranax
CDN1200No response detected between ENQ-ACK after 5 retries of ENQHyosung
CDN13No response detected after 5 retries because of timeout between STX-BCC intervalTranax
CDN1300No response detected after 5 retries because of timeout between STX-BCC intervalHyosung
CDNxxCDU connection failureTranax
CDNXX00Cash Dispenser Unit connection failureControl Electronics<-> Cash Dispenser Unit communication errorHyosung
Change floppy errorTidel
D00Cannot receive ENQ from hostTriton
D0000Settlement ErrorTranax
D0001Modem initializing errorTranax
D0001Modem initializing failure.Genmega
D000100Error while modem initializingTranax
D000100Error while modem initializingHyosung
D0002Reversal transaction failed.Tranax
D0002Reversal transaction failed.Genmega
D000200Reversal transaction failureTranax
D000200Reversal transaction failureHyosung
D0003Pin ErrorTranax
D000300PIN ERRORTranax
D000300PIN ERRORHyosung
D0004Invalid Pin ErrorTranax
D000400INVALID PINTranax
D000400INVALID PINHyosung
D0005Bank UnavailableTranax
D000500BANK UNAVAILABLETranax
D000500BANK UNAVAILABLEHyosung
D0006Card not supportedTranax
D0006Card not supportedHyosung
D000600CARD NOT SUPPORTEDTranax
D000600CARD NOT SUPPORTEDHyosung
D0007Insufficient FundsTranax
D000700INSUFFICIENT FUNDSTranax
D000700INSUFFICIENT FUNDSHyosung
D0008Ineligible transactionTranax
D000800INELIGIBLE TRANSACTIONTranax
D000800INELIGIBLE TRANSACTIONHyosung
D0009Ineligible accountTranax
D000900INELIGIBLE ACCOU NTTranax
D000900INELIGIBLE ACCOUNTHyosung
D0010Daily limit exceededTranax
D001000DAILY LIMIT EXCEEDEDTranax
D001000DAILY LIMIT EXCEEDEDHyosung
D0011Unable to processTranax
D0011 ~ D0099Request to dispense 0 note. Command error in the Control Electronics control partTranax
D001100UNABLE TO PROCESSTranax
D001100UNABLE TO PROCESSHyosung
D0012Invalid TransactionTranax
D0012Invalid transaction.Genmega
D001200Invalid transactionTranax
D001200Invalid transactionHyosung
D0013Invalid AmountTranax
D0013Invalid Amount.Genmega
D001300Invalid amountTranax
D001300Invalid amountHyosung
D0014Invalid Card NumberTranax
D0014Invalid Card Number.Genmega
D0014Invalid card numberHyosung
D001400Invalid card numberTranax
D001400Invalid card numberHyosung
D0015Unable to process.Tranax
D001500UNABLE TO PROCESSTranax
D001500UNABLE TO PROCESSHyosung
D0016Withdrawal limit already reached.Tranax
D001600WITHDRAWAL LIMIT ALREADY REACHEDTranax
D001600WITHDRAWAL LIMIT ALREADY REACHEDHyosung
D0017Invalid amount.Tranax
D001700INVALID AMOUNTTranax
D001700INVALID AMOUNTHyosung
D0018External declineTranax
D001800EXTERNAL DECLINETranax
D001800EXTERNAL DECLINEHyosung
D0019System errorTranax
D001900SYSTEM ERRORTranax
D001900SYSTEM ERRORHyosung
D0020Surcharge screen should have been displayedTranax
D0020Surcharge screen should have been displayed.Genmega
D002000Surcharge screen should have been displayed Tranax
D002000Surcharge screen should have been displayedHyosung
D0021Routing lookup problemTranax
D002100ROUTING LOOKUP PROBLEMTranax
D002100ROUTING LOOKUP PROBLEMHyosung
D0022Unable to processTranax
D002200UNABLE TO PROCESSTranax
D002200UNABLE TO PROCESSHyosung
D0023Transaction not supportedTranax
D002300TRANSACTION NOT SUPPORTEDTranax
D002300TRANSACTION NOT SUPPORTEDHyosung
D0024Exceeds issuer withdrawal limitTranax
D0024Undefined ErrorGenmega
D002400Exceeds Issuer Withdrawal LimitTranax
D002400Exceeds Issuer Withdrawal LimitHyosung
D0039No credit accountTranax
D0039No credit account.Genmega
D003900No Credit AccountTranax
D003900No Credit AccountHyosung
D0051Insufficient fundsTranax
D0051Insufficient funds.Genmega
D005100Insufficient FundsTranax
D005100Insufficient FundsHyosung
D0052No checking accountTranax
D0052No checking account.Genmega
D005200No Checking AccountTranax
D005200No Checking AccountHyosung
D0053No savings accountTranax
D0053No savings account.Genmega
D005300No Savings AccountTranax
D005300No Savings AccountHyosung
D0054Expired CardTranax
D0054Expired Card.Genmega
D0054Expire CardHyosung
D005400Expire CardTranax
D005400Expire CardHyosung
D0055Invalid PINTranax
D0055Invalid PIN.Genmega
D005500Incorrect PinTranax
D005500Incorrect PinHyosung
D0057Transaction not permitted - cardTranax
D0057"Transaction not permitted �
card"Genmega
D0057Transaction not permittedHyosung
D005700Transaction not Permitted � CardTranax
D005700Transaction not Permitted � CardHyosung
D0058Transaction not permitted - TerminalTranax
D0058Transaction not permitted � TerminalGenmega
D005800Transaction not Permitted � TerminalTranax
D005800Transaction not Permitted � TerminalHyosung
D0061Exceeded withdrawal limitTranax
D0061Exceed withdrawal limit.Genmega
D006100Exceeds Withdrawal LimitTranax
D006100Exceeds Withdrawal LimitHyosung
D0075Number of PIN tries exceededTranax
D0075Number of PIN tries exceeded.Genmega
D007500PIN Tries ExceededTranax
D007500PIN Tries ExceededHyosung
D0078No AccountTranax
D0078No Account.Genmega
D007800No AccountTranax
D007800No AccountHyosung
D0080Invalid DateTranax
D0080Invalid Date.Genmega
D008000Invalid DateTranax
D008000Invalid DateHyosung
D0083Cannot verify PINTranax
D0083Cannot verify PIN.Genmega
D008300Can not Verify PINTranax
D008300Can not Verify PINHyosung
D0086Cannot verify PINTranax
D0086Cannot verify PIN.Genmega
D008600Can not Verify PINTranax
D008600Can not Verify PINHyosung
D0091Bank unavailableTranax
D0091Bank unavailable.Genmega
D009100Bank UnavailableTranax
D009100Bank UnavailableHyosung
D009130STX errorTranax
D0092System unavailableTranax
D0092System unavailable.Genmega
D009200System UnavailableTranax
D009200System UnavailableHyosung
D0093Transaction serial number mismatchTranax
D0093Transaction serial number mismatch.Genmega
D009300Transaction Serial Number mismatchTranax
D009300Transaction Serial Number mismatchHyosung
D0094Record format mismatchTranax
D0094Record format mismatch.Genmega
D009400Record format mismatch.Tranax
D009400Record format mismatch.Hyosung
D0095Routing ID mismatchTranax
D0095Routing ID mismatch.Genmega
D009500Routing ID mismatch.Tranax
D009500Routing ID mismatch.Hyosung
D0096Terminal ID mismatchTranax
D0096Terminal ID mismatch.Genmega
D009600Terminal ID mismatch.Tranax
D009600Terminal ID mismatch.Hyosung
D0097Response type mismatch (reversal)Tranax
D0097"Response type mismatch
(reversal)."Genmega
D009700Response Type mismatch (Reversal)Tranax
D009700Response Type mismatch (Reversal)Hyosung
D0098Response type mismatch (day-close)Tranax
D0098"Response type mismatch
(day-close)."Genmega
D009800Response Type mismatch (Day Close)Tranax
D009800Response Type mismatch (Day Close)Hyosung
D0099Response type mismatch (Configuration)Tranax
D0099"Response type mismatch
(Configuration)."Genmega
D009900Response Type mismatch (Config.)Tranax
D009900Response Type mismatch (Config.)Hyosung
D009A"Response type mismatch (Withdrawal Balance Transfer)"Tranax
D009A"Response type mismatch
(Withdrawal Balance Transfer)."Genmega
D009A ~Note jamCS1?CS4(NS2~NS3) : Note Passting Time >= 400msCS4~CS13(NS3~NS4) : Note Passting Time >= 500msOccurs while notes are being dispensed.Tranax
D009A00"Response Type mismatch
(Withdrawal/Balance/Transfer)"Hyosung
D009BSTX omittedTranax
D009BSTX omitted.Genmega
D009B00STX errorHyosung
D009CETX omittedTranax
D009CETX omitted.Genmega
D009C00ETX errorTranax
D009C00ETX errorHyosung
D009DFS omitted (after response code)Tranax
D009DFS omitted (after response code).Genmega
D009D00FS out (after response code)Tranax
D009D00FS out (after response code)Hyosung
D009EFS omitted (after retrieval reference number)Tranax
D009EFS omitted (after retrieval reference number).Genmega
D009E00FS out (after retrieval reference number)Tranax
D009E00FS out (after retrieval reference number)Hyosung
D009FFS omitted (after system trace audit number)Tranax
D009FFS omitted (after system trace audit number).Genmega
D009F00FS out (after system trace audit number)Tranax
D009F00FS out (after system trace audit number)Hyosung
D00A0FS omitted (after account balance)Tranax
D00A0FS omitted (after account balance).Genmega
D00A000FS out (after account balance)Tranax
D00A000FS out (after account balance)Hyosung
D00A1FS omitted (after available balance)Tranax
D00A1FS omitted (after available balance).Genmega
D00A100FS out (after available balance)Tranax
D00A100FS out (after available balance)Hyosung
D00A2FS omitted (after available balance)Tranax
D00A2FS omitted (after available balance).Genmega
D00A200FS out (after surcharge amount)Tranax
D00A200FS out (after surcharge amount)Hyosung
D00A3FS omitted (after authorization response text)Tranax
D00A3FS omitted (after authorization response text).Genmega
D00A300FS out (after authorization response text)Tranax
D00A300FS out (after authorization response text)Hyosung
D00A4ETX is in wrong placeTranax
D00A4ETX is in wrong place.Genmega
D00A400ETX wrong positionTranax
D00A400ETX wrong positionHyosung
D00A5FS omitted (after total cash dispense amount in day close)Tranax
D00A5"FS omitted (after total cash dispense amount in day
close)."Genmega
D00A500FS out (after total cash dispense amount)Tranax
D00A500FS out (after total cash dispense amount)Hyosung
D00A6FS omitted (after total non cash dispense amount in day close)Tranax
D00A6"FS omitted (after total non cash dispense amount in day
close)."Genmega
D00A600FS out (after total non-cash dispense amount)Tranax
D00A600FS out (after total non-cash dispense amount)Hyosung
D00A7FS omitted (after surcharge amount in day close message)Tranax
D00A7"FS omitted (after surcharge amount in day close
message)."Genmega
D00A700FS out (after total surcharge amount)Tranax
D00A700FS out (after total surcharge amount)Hyosung
D00A8FS omitted (after surcharge amount in configuration message)Tranax
D00A8FS omitted (after surcharge in configuration message).Genmega
D00A800FS out (after config surcharge amount)Tranax
D00A800FS out (after config surcharge amount)Hyosung
D00A9ETX omitted (from configuration message)Tranax
D00A9ETX omitted (from configuration message).Genmega
D00A900ETX out (config)Tranax
D00A900ETX out (config)Hyosung
D00AAResponse Code ErrorTranax
D00ABMiscellaneous Field ErrorTranax
D00ACAmount ErrorTranax
D00AC00Invalid data received from the host (MAC data mismatch)Tranax
D00AC00Invalid data received from the host (MAC data mismatch)Hyosung
D00ADResponse Data ErrorTranax
D00AESequence Number ErrorTranax
D00B0Mismatch Terminal I.D.Tranax
D00B000TERMINAL ID MISMATCHEDTranax
D00B000TERMINAL ID MISMATCHEDHyosung
D00B1Mismatch transaction codeTranax
D00B100TRANSACTION CODE MISMATCHEDTranax
D00B100TRANSACTION CODE MISMATCHEDHyosung
D00B2Mismatch field I.D. codeTranax
D00B200SECOND FIELD ID CODE MISMATCHEDTranax
D00B200SECOND FIELD ID CODE MISMATCHEDHyosung
D00B3Mismatch incription pinTranax
D00B300FIRST DES KEY WRONG SIZETranax
D00B300FIRST DES KEY WRONG SIZEHyosung
D00B4Mismatch field I.D. codeTranax
D00B400SURCHARGE AMOUNT WRONG SIZETranax
D00B400SURCHARGE AMOUNT WRONG SIZEHyosung
D00B5Mismatch sequence numberTranax
D00B500Sequence Number MISMATCHEDTranax
D00B500Sequence Number MISMATCHEDHyosung
D00B6Mismatch response codeTranax
D00B600INVALID RESPONSE CODE ERRORTranax
D00B600INVALID RESPONSE CODE ERRORHyosung
D00B7Mismatch authorization numberTranax
D00B700Authorization Number ErrorTranax
D00B700Authorization Number ErrorHyosung
D00B8Mismatch transaction dateTranax
D00B800BUSINESS DATE ErrorTranax
D00B800BUSINESS DATE ErrorHyosung
D00B9Mismatch transaction timeTranax
D00B900Transaction time Number ErrorTranax
D00B900Transaction time Number ErrorHyosung
D00BAMismatch business dateTranax
D00BA00BUSINESS DATE ErrorTranax
D00BA00BUSINESS DATE ErrorHyosung
D00BBMismatch balance amountTranax
D00BB00Balance amount ErrorTranax
D00BB00Balance amount ErrorHyosung
D00BCMismatch surcharge amountTranax
D00BC00Actual Surcharge ErrorTranax
D00BC00Actual Surcharge ErrorHyosung
D00BDMismatch sequence numberTranax
D00BD00Sequence Number MISMATCHEDTranax
D00BD00Sequence Number MISMATCHEDHyosung
D00BEMismatch response codeTranax
D00BFMismatch business dateTranax
D00BF00BUSINESS DATE ErrorTranax
D00BF00BUSINESS DATE ErrorHyosung
D00C0Settlement ErrorTranax
D00C000Settlement ErrorHyosung
D00C100Host Mac result errorTranax
D00C100Host Mac result errorHyosung
D00C200ATM Mac result errorTranax
D00C200ATM Mac result errorHyosung
D01ATM is onlineTriton
D0111Reversal DeclinedTranax
D011100REVERSAL DECLINEDTranax
D011100REVERSAL DECLINEDHyosung
D02ATM is onlineTriton
D0222Pin DeclinedTranax
D022200PIN CHANGE DECLINEDTranax
D022200PIN CHANGE DECLINEDHyosung
D0300Modem is not respondingTranax
D0300Modem is not responding.Genmega
D030000Modem is not respondingTranax
D030000Modem is not respondingHyosung
D0301The target call address has call blocking enabled.Tranax
D030100The target call address has call blocking enabled.Tranax
D030100The target call address has call blocking enabled.Hyosung
D0302The specified terminal identifier is invalid.Tranax
D030200The specified terminal identifier is invalid.Tranax
D030200The specified terminal identifier is invalid.Hyosung
D0303All call appearances on the specified address are currently in use.Tranax
D030300All call appearances on the specified address are currently in use.Tranax
D030300All call appearances on the specified address are currently in use.Hyosung
D0304The disable address parameter containsdialing control characters that are notprocessed by the service provider.Tranax
D030400The disable address parameter contains dialing control characters that are not processed by the service provider.Tranax
D030400The disable address parameter contains dialing control characters that are not processed by the service provider.Hyosung
D0305The specified country/region code is invalid.Tranax
D030500The specified country/region code is invalid.Tranax
D030500The specified country/region code is invalid.Hyosung
D0306The operation failed for an unspecified or unknown reason.Tranax
D030600The operation failed for an unspecified orunknown reason.Tranax
D030600The operation failed for an unspecified or unknown reason.Hyosung
D0307Insufficient resources to complete the operationTranax
D030700Insufficient resources to complete the operationTranax
D030700Insufficient resources to complete the operationHyosung
D04ATM is onlineTriton
D06ATM is onlineTriton
D1000No ConnectionTranax
D1000No Connection.Genmega
D100000No connectionTranax
D100000No connectionHyosung
D11No errorsTriton
D1100ENQ not received from hostTranax
D1100ENQ not received from host.Genmega
D110000Cannot receive ENQ from the hostTranax
D110000Cannot receive ENQ from the hostHyosung
D1200Transmission errorTranax
D1200Transmission error.Genmega
D120000Transmission error : Failed to receive the whole data within 5 seconds after requesting the modem to send the data.Tranax
D120000Transmission error : Failed to receive the whole data within 5 seconds after requesting the modem to send the data.Hyosung
D1300NAK sent 3 times to hostTranax
D1300NAK sent 3 times to host.Genmega
D130000Receiving NAK more than 3 timesTranax
D130000Receiving NAK more than 3 timesHyosung
D14Invalid Card NumberTriton
D1401Disconnected by Unknown ReasonTranax
D140100Disconnected by Unknown ReasonTranax
D140100Disconnected by Unknown ReasonHyosung
D1402Disconnected by rejected call from remote partyTranax
D140200Disconnected by rejected call from remote partyTranax
D140200Disconnected by rejected call from remote partyHyosung
D1403Disconnected because the local phone was picked upTranax
D140300Disconnected because the local phone was picked upTranax
D140300Disconnected because the local phone was picked upHyosung
D1404Disconnected by ForwardedTranax
D140400Disconnected by ForwardedTranax
D140400Disconnected by ForwardedHyosung
D1405Disconnected by UnreachableTranax
D140500Disconnected by UnreachableTranax
D140500Disconnected by UnreachableHyosung
D1406Disconnected by CongestionTranax
D140600Disconnected by CongestionTranax
D140600Disconnected by CongestionHyosung
D1407Disconnected by IncompatibleTranax
D140700Disconnected by IncompatibleTranax
D140700Disconnected by IncompatibleHyosung
D1408Disconnected by un-known reasonTranax
D140800Disconnected by un-known reasonTranax
D140800Disconnected by un-known reasonHyosung
D1409Disconnected by Bad AddressTranax
D140900Disconnected by Bad AddressTranax
D140900Disconnected by Bad AddressHyosung
D1410Disconnected by UnavailableTranax
D141000Disconnected by UnavailableTranax
D141000Disconnected by UnavailableHyosung
D1500Modem connection time out - host not respondingTranax
D1500"Modem connection time out �
host not responding."Genmega
D1500001.Modem dial connection time-out(while dialing the modem).2.No response from host for 60 seconds.Tranax
D150000"1. Modem dial connection time-out
(while dialing the modem).
2. No response from host for 60 seconds."Hyosung
D16ATM is onlineTriton
D1601Disconnected by Bad AddressTranax
D160100Disconnected by Bad AddressTranax
D160100Disconnected by Bad AddressHyosung
D1602Disconnected by UnavailableTranax
D160200Disconnected by UnavailableTranax
D160200Disconnected by UnavailableHyosung
D1603Disconnected by Out of OrderTranax
D160300Disconnected by Out of OrderTranax
D160300Disconnected by Out of OrderHyosung
D1700No carrier (while sending/receiving data after dial connection)Tranax
D170000No carrier (while sending/receiving data after dial connection)Tranax
D170000No carrier (while sending/receiving data after dial connection)Hyosung
D1701No carrierTranax
D170100No Carrier during ENQ data receive from hostTranax
D170100No Carrier during ENQ data receive from hostHyosung
D1702No carrierTranax
D170200No Carrier before sending data send to hostTranax
D170200No Carrier before sending data send to hostHyosung
D1703No carrierTranax
D170300No Carrier during sending data send to hostTranax
D170300No Carrier during sending data send to hostHyosung
D1704No carrierTranax
D170400No Carrier during ACK/NAK data send to hostTranax
D170400No Carrier during ACK/NAK data send to hostHyosung
D1705No carrierTranax
D170500No Carrier during ACK/NAK data receive from hostTranax
D170500No Carrier during ACK/NAK data receive from hostHyosung
D1706No carrierTranax
D170600No Carrier during receiving dataTranax
D170600No Carrier during receiving dataHyosung
D170700NAK retry error.Tranax
D170700NAK retry error.Hyosung
D170800Send retry errorTranax
D170800Send retry errorHyosung
D170900Modem initialize failTranax
D170900Modem initialize failHyosung
D170xModem cannot support connection - excessive line noise (usually D1704/06)Tranax
D170x"Modem cannot support connection � excessive line
noise (usually D1704/06)"Genmega
D170X00No carrierNo carrier during data transmission after the modem is connected.Hyosung
D171000Modem Comport FailedTranax
D171000Modem Comport FailedHyosung
D1800No dial toneTranax
D1800No dial tone.Genmega
D180000No Dial Tone(in Modem dial connection)Tranax
D180000No Dial Tone(in Modem dial connection)Hyosung
D1900No answerTranax
D1900No answer.Genmega
D190000No AnswerTranax
D190000No AnswerHyosung
D2000Phone line BusyTranax
D2000Phone line busy.Genmega
D200000Dial(Line) busyTranax
D200000Dial(Line) busyHyosung
D2100Modem initializing errorTranax
D2100Modem initializing error.Genmega
D210000Time out(30sec.) for initializing modem before Modem Dial connectingTranax
D210000"Time out(30sec.) for initializing modem before
Modem Dial connecting"Hyosung
D2200EOT not received from hostTranax
D2200EOT not received from host.Genmega
D220000not receiving EOT from HOSTTranax
D220000not receiving EOT from HOSTHyosung
D2300No response from Host - Dialing time out to HostTranax
D230000No response from Host - Dialing time out to HostTranax
D230000No response from Host - Dialing time out to HostHyosung
D2500Cannot connect to the host Check the connectionTranax
D250000Cannot connect to the hostTranax
D250000Cannot connect to the hostHyosung
D2510Timeout while SendingTranax
D251000Timeout while SendingTranax
D251000Timeout while SendingHyosung
D2511Communication error while Sending. (This is very common with new broadband/DSL setups. Normally this problem stemsTranax
D251100Communication error while SendingTranax
D251100Communication error while SendingHyosung
D2512Socket error while SendingTranax
D251200Socket error while SendingTranax
D251200Socket error while SendingHyosung
D2513Timeout while ReceivingTranax
D251300Timeout while ReceivingTranax
D251300Timeout while ReceivingHyosung
D2514Communication error while ReceivingTranax
D251400Communication error while ReceivingTranax
D251400Communication error while ReceivingHyosung
D2515Socket Error while ReceivingTranax
D251500Socket Error while ReceivingTranax
D251500Socket Error while ReceivingHyosung
D25xxNetwork ConnectionGenmega
D3200Dial connect time out (60 seconds)Tranax
D320000No response from Host/Dialing time out to HostTranax
D320000No response from Host/Dialing time out to HostHyosung
D3201Outbound call is abortedTranax
D320100Outbound call is abortedTranax
D320100Outbound call is abortedHyosung
D3202Fail to dial outTranax
D320200Fail to dial outTranax
D320200Fail to dial outHyosung
D3203No Line ReplyTranax
D320300No Line ReplyTranax
D320300No Line ReplyHyosung
D3204Get Line ID FailedTranax
D320400Get Line ID FailedTranax
D320400Get Line ID FailedHyosung
D3205Modem Comport FailedTranax
D320500Modem Comport FailedTranax
D320500Modem Comport FailedHyosung
D3206Call FailedTranax
D320600Call FailedTranax
D320600Call FailedHyosung
D3207No AnswerTranax
D320700No AnswerTranax
D320700No AnswerHyosung
D3208Modem Call Other ErrorTranax
D320800Modem Call Other ErrorTranax
D320800Modem Call Other ErrorHyosung
D410000CRC MismatchTranax
D410000CRC MismatchHyosung
D410100No CRC ReceivedTranax
D410100No CRC ReceivedHyosung
DA00010Expired cardTranax
DA00020Unauthorized usageTranax
DA00030PIN errorTranax
DA00040Invalid PINTranax
DA00050Bank unavailableTranax
DA00060Card not supportedTranax
DA00070Insufficient fundsTranax
DA00080Ineligible transactionTranax
DA00090Ineligible accountTranax
DA00100Number of daily withdrawals exceededTranax
DA00110Cannot process transactionTranax
DA00120Amount too largeTranax
DA00130Account closedTranax
DA00140PIN tries exceededTranax
DA00150Database problemTranax
DA00160Withdrawal limit already reachedTranax
DA00170Invalid amountTranax
DA00180External declineTranax
DA00190System errorTranax
DA00200Contact card issuerTranax
DA00210Routing lookup problemTranax
DA00220Message edit errorTranax
DA00230Transaction not supportedTranax
DA00240Insufficient fundsTranax
DA00250Western Union sender data errorTranax
DA00260Western Union receiver data errorTranax
DA00270CRC errorTranax
DA00280Pre-pay transaction failedTranax
DA00290Pre-pay transaction rejectedTranax
DA00300Invalid mobile phone numberTranax
DA00310Pre-pay account limit reachedTranax
DA00320Pre-pay system unavailableTranax
DA00330Response would exceed message size limitTranax
DA00340Necessary information missing to process transactionTranax
DA00350Second Invalid PIN (second invalid PIN try in a row and one try is left before deactivation)Tranax
DA00360Fallback Not AllowedTranax
DA01110Reversal DeclinedTranax
DA02220PIN Change DeclinedTranax
DA02230PIN Unlock DeclinedTranax
DA0xxx0Host Denial ErrorTranax
DA0xxx0Host Denial ErrorHyosung
Delivery failureTidel
Diverter ErrorTidel
DOO9A00Response Type mismatch (Withdrawal/Balance/Transfer)Tranax
Door open with no logonTidel
Double detect mistrackTidel
Download card removal displayTidel
Dxx011st Cassette Miss-feedTranax
Dxx02Incorrect bill countTranax
E0001RMS port failureTranax
E000100RMS port failureHyosung
E0002RMS response time-outTranax
E000200RMS response time-outHyosung
E0003RMS modem failureTranax
E000300RMS modem failureHyosung
E0004RMS no dial toneTranax
E000400RMS no dial toneHyosung
E0005RMS MODEM Disconnetion time outTranax
E000x"RMS port failure response time out modem failure no dial tone"Tranax
E000x"RMS port failure response time out modem failure no
dial tone."Genmega
E1000S/W internal Timeout between AP and TAPI or DriverTranax
Empty cassette(s)Tidel
Eprom errorTidel
ERJChip card read errorTriton
Error Description Triton
Error CodeDescriptionTriton
Error CodeDescriptionGenmega
Error CodeDescriptionHyosung
Error CodeDescriptionTranax
Error writing to flashTidel
Exit MistrackTidel
Exit QuantifiedTidel
Exit Sensor BlockedTidel
Exit Sensor DirtyTidel
F0001Current Number of Bills is 0Tranax
F0001Current Number of bill is 0.Genmega
F000100Number of Bill is not inputtedTranax
F000100Number of Bill is not inputtedHyosung
F0002No Surcharge Owner setTranax
F0002No Surcharge Owner set.Genmega
F000200Parameter is not properly set (Surcharge Owner)Tranax
F000200Parameter is not properly set (Surcharge Owner)Hyosung
F0003No Surcharge AmountTranax
F0003No Surcharge Amount.Genmega
F000300Parameter is not properly set (Surcharge Amount)Tranax
F000300"Parameter is not properly set (Surcharge
Amount)"Hyosung
F0004No refresh timer set when advertisement is enabledTranax
F0004No refresh time set when advertisement is enabled.Genmega
F000400Parameter is not properly set (Adver. Text refreshing timer)Tranax
F000400Parameter is not properly set (Adver. Text refreshing timer)Hyosung
F0005No Advertisement text when advertisement is enabledTranax
F0005No Advertisement text when advertisement is enabled.Genmega
F000500Parameter is not properly set (Advertisement text)Tranax
F000500Parameter is not properly set (Advertisement text)Hyosung
F0006Dispense limit set error (must be less than 25 notes)Tranax
F0006Dispense limit set error (less than 25 notes)Genmega
F000600Parameter is not properly set (Dispense limit)Tranax
F000600Parameter is not properly set (Dispense limit)Hyosung
F0007Denomination Set errorTranax
F0007Denomination Set error.Genmega
F000700Parameter is not properly set (Denomination)Tranax
F000700Parameter is not properly set (Denomination)Hyosung
F0008Fast Cash Set error (cannot exceed dispense limit)Tranax
F0008Fast Cash Set error (exceeded dispense limit).Genmega
F000800Parameter is not properly set (Fast Cash)Tranax
F000800Parameter is not properly set (Fast Cash)Hyosung
F0009Master Key index is invalidTranax
F0009Master Key index is invalid.Genmega
F000900Master Key Index invalidTranax
F000900Master Key Index invalidHyosung
F000AMaster Key is emptyTranax
F000AMaster Key emptyGenmega
F000A00Master Key emptyTranax
F000A00Master Key emptyHyosung
F000BHost Telephone Number is not setTranax
F000BHost Phone Number isn't setGenmega
F000B00Host Phone Number is not inputtedTranax
F000B00Host Phone Number is not inputtedHyosung
F000CError Retry timer is not setTranax
F000CRetry Timer is not setGenmega
F000C00Error Retry Timer is not inputtedTranax
F000C00Error Retry Timer is not inputtedHyosung
F000DRMS Password is not set when RMS is enabledTranax
F000DRMS password isn't setGenmega
F000D00RMS Password is not inputted in RMS EnableTranax
F000D00RMS Password is not inputted in RMS EnableHyosung
F000ERMS phone number is not set when RMS send is enabledTranax
F000ERMS phone number isn't setGenmega
F000E00RMS Phone Number is not inputted in RMS EnableTranax
F000E00RMS Phone Number is not inputted in RMS EnableHyosung
F000FTerminal ID is not setTranax
F000FTerminal number isn't setGenmega
F000F00Terminal Number is not inputtedTranax
F000F00Terminal Number is not inputtedHyosung
F0010Routing ID is not setTranax
F0010Routing ID isn't setGenmega
F001000Routing ID is not inputtedTranax
F001000Routing ID is not inputtedHyosung
F0011Master Key Serial number is not setTranax
F0011Master Key serial number isn't setGenmega
F001100Master Key Serial Number is not inputtedTranax
F001100Master Key Serial Number is not inputtedHyosung
F0012Non-cash type text not setTranax
F001200Non-Cash Type text is not inputtedTranax
F001200Non-Cash Type text is not inputtedHyosung
F0013
NV Ram failureGenmega
F0013
14"UndefinedGenmega
F0013NVRAM FailureTranax
F0013/14NVRM Failure.Tranax
F001300Parameter is not properly setTranax
F001300Parameter is not properly setHyosung
F0014NVRAM failureTranax
F0014NV Ram failureGenmega
F001400NVRAM FailureTranax
F001400NVRAM FailureHyosung
F0015ATM Serial No. EmptyTranax
F0015ATM serial number emptyGenmega
F001500ATM Serial No. EmptyTranax
F001500ATM Serial No. EmptyHyosung
F0016Default master password was not changedTranax
F0016Default master password was not changedGenmega
F001600Default master password was not changedTranax
F001600Default master password was not changedHyosung
F001FMachine serial number is not setTranax
F001F00Machine serial number is not setTranax
F001F00Machine serial number is not setHyosung
F002FHost type is not setTranax
F002F00Host type is not setTranax
F002F00Host type is not setHyosung
F003FCommunication ID invalid (only triton)Tranax
F003F00Communication ID invalid (only triton)Tranax
F003F00Communication ID invalid (only triton)Hyosung
F004FEPP(Pinpad) key mode is invalidTranax
F004F00EPP(Pinpad) key mode is invalidTranax
F004F00EPP(Pinpad) key mode is invalidHyosung
F005FDenomination is invalidTranax
F005F00Denomination is invalid1.Check modem cableTranax
F005F00Denomination is invalidHyosung
F006FFailed Host Connection!Tranax
F006F00Failed Host Connection!Tranax
F006F00Failed Host Connection!Hyosung
F007F00Invalid Exchange RateTranax
F007F00Invalid Exchange RateHyosung
F00FF00Failed to write JournalTranax
F00FF00Failed to write JournalHyosung
Feed FailureTidel
Feed MistrackTidel
Feed Sensor BlockedTidel
FFFFFFFNVRAM is brokenTranax
FFFFFFFNVRAM is brokenHyosung
Floppy Drive not RespondingTidel
Floppy in useTidel
Floppy Read ErrorTidel
Floppy Write ErrorTidel
Floppy write receipt errorTidel
Host msg 96 � Invalid msg sequenceTidel
Host msg 97 � Bad sequence #Tidel
Host msg 99 � Bad terminal IDTidel
Host type 2 � Dispense amount errorTidel
Host type 2 errorTidel
IDN0XMCR connection failureTranax
IDN0XDIP MCR connection failureHyosung
IDN0X00DIP MCR connection failureHyosung
IDNOXDIP MCR connection failureTranax
Interface RecoveryTidel
Jam at ExitTidel
Jam in Note QualifierTidel
Jam in Note StackerTidel
Jam in Note TransportTidel
LID on floppyTidel
Link ErrorTidel
M01Card Reader ErrorTriton
MF1Hardware MalfunctionTriton
Must perform close outTidel
Must read NMD ID�sTidel
MX-5000XP with SIDECARHyosung
NHB09Password/Terminal I.D. not matching.Tranax
NMD Com Time OutTidel
NMD Data CorruptTidel
NMD Error � Power or cablesTidel
NMD Illegal commandTidel
NMD Lifts are DownTidel
NMD Main Motor FailureTidel
NMD Module needs serviceTidel
NMD Sensor errorTidel
NMD Shutter FailureTidel
NMD Throat ErrorTidel
NMD Transmission ErrorTidel
No Floppy in driveTidel
No Note at Double DetectTidel
No Notes RetractedTidel
Note Qualifier FaultyTidel
Note Too Long at ExitTidel
Notes in Delivery ThroatTidel
Operation TimeoutTidel
P01Keypad Comm ErrorTriton
Paper LowTidel
POWERABUPS ABNORMALTranax
POWERABUPS ABNORMALHyosung
POWERACPOWER OUT OR AC OFFTranax
POWERACPOWER OUT OR AC OFFHyosung
POWERBABATTERY LOWTranax
POWERBABATTERY LOWHyosung
Printer TimeoutTidel
Printer Timeout cont.Tidel
Ram CorruptionTidel
Ram ErrorTidel
Reject Bin not InstalledTidel
Reject Cassette almost fullTidel
Reject Cassette FullTidel
Reject FailureTidel
Reject rate exceededTidel
RXXATM Is onlineTriton
Scheduler/Kernel ErrorTidel
SDN01Service Panel (SPL) communication errorTranax
SDN0100Service Panel (SPL) communication errorTranax
SDN0100Service Panel (SPL) communication errorHyosung
Select cash amount errorTidel
Suspect Exit AccountancyTidel
Telephone Modem Problem"Tidel
Timing WheelTidel
Too many notesTidel
Too many notes requestedTidel
Turn off audio alarmTidel
TX File date errorTidel
Vend ShortTidel
Waiting Reversal CompletionTidel
Wrong countTidel
wwwnewnewTranax
xxxxxtestTriton

Get in touch with us

Your message was sent successfully
Thank you!